User's Manual
Troubleshootin
g
Booth Control
Troubleshooting
Figure 8 Booth Control
Figure 9 Bottom View of Booth Control
Table 1 . Booth Control Diagnostics
Indicator Description Diagnosis
Mix Mode (green)
LEDisonwheninMixmode.
LED blinks when in Mix Fill mode. Also blinks is Mix Idle
mode (together with Standby LED).
Purge Mode (green)
LED is on when in Purge mode.
LED blinks when a purge is needed.
Pressure Change Mode
(green)
LED blinks when in Pressure Change mode.
Alarm (red)
LED is on steady when any event has been acknowledged.
LED blinks when any event has not been acknowledged.
LED turns off after the event is cleared.
Standby Mode (green) LED is on steady when in Standby mode.
LED blinks when in Color Change, Startup, Shutdown,
Prime Pump, Fill, Calibration, Maintenance, and during
Pump Pressure Check. Also blinks is Mix Idle mode
(together with Mix LED).
D8
Heartbeat (green)
LED blinks during normal operation.
D9
Communication (yellow)
LED turns on when board is communication with isolation
board in electronic control.
D10
Power (green)
LED turns on when power is supplied to the board
(connector J11).
J11
Connector Power/CAN connector.
2
2
3A2800B