User's Manual

Repair
Replacing a Solenoid
NOTICE
To avoid damag
ing the circuit boards when
servicing the
control box, wear Part No. 112190
grounding st
rap on your wrist and ground
appropriate
ly.
To avoid electrical component damage, remove all
system power before plugging any connectors.
1. Follow the steps in Before Servicing, page 36.
2. Remove the screws (56) holding the cover (8)
to the front of the unit.
3. Loosen the screws (124) and remove the
enclosure cover (117).
4. Disconnect the 2 solenoid wires from
J1 on the pump control module. See
Electrical Schematics, page 29.
5. Remove 2 screws (303) and the solenoid (305).
6. Install the new solenoid (305) with the screws
(303).
7. Connect the 2 solenoid wires to J1
on the pump control module. See
Electrical Schematics, page 29.
8. Replace the covers (8, 117).
Figure 37
Solenoid Replacement