User's Manual

Warnings
WARNING
INTRINSIC SAFETY
Intrinsically safe equipment that is installed improperly or connected to non-intrinsically safe
equipment will create a hazardous condition and can cause fire, explosion, or electric shock.
Follow local regulations and the following safety requirements.
•Besureyouri
nstallation complies with national, state, and local codes for the installation of
electrical a
pparatus in a Class I, Group D, Division 1 (North America) or Class I, Zones 1
and 2 (Europ
e) Hazardous Location, including all of the local safety fire codes (for example,
NFPA 33, NEC
500 and 516, OSHA 1910.107, etc.).
To help prevent fire and explosion:
Do not install equipment approved only for a non-hazardous location in a hazardous
location. See model ID label for the intrinsic safety rating of your model.
Do not subs
titute system components as this may impair intrinsic safety.
Equipment that comes in contact with the intrinsically safe terminals must be rated for Intrinsic
Safety. This includes DC voltage meters, ohmmeters, cables, and connections. Remove the
unit from the hazardous area when troubleshooting.
SKIN INJECTION HAZARD
High-pressure fluid from gun, hose leaks, or ruptured components will pierce skin. This may
look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical
treatment.
Do not sp
ray without tip guard and trigger guard installed.
Engage trigger lock when not spraying.
Do not point gun at anyone or at any part of the body.
•Donotp
ut your hand over the spray tip.
Do not stop or deflect leaks with your hand, body, glove, or rag.
Follow the Pressure Relief Procedure when you stop spraying/dispensing and before
cleaning, checking, or servicing equipment.
•Tight
en all fluid connections before operating the equipment.
Check hoses and couplings daily. Replace worn or damaged parts immediately.
MOVING PARTS HAZARD
Moving parts can pinch, cut or amputate fingers and other body parts.
Keep clear of moving parts.
Do not operate equipment with protective guards or covers removed.
•Pre
ssurized equipment can start without warning. Before checking, moving, or servicing
equ
ipment, follow the Pressure Relief Procedure and disconnect all power sources.
3A2800B
7