User's Manual

Setup
34 3A2894F
1. Purge Material Lines.
a. Load material.
Ram: Perform the “Change Drums” procedure
in the Air-Powered Ram manual.
Pressure Pot: Perform “Filling the Tank” proce-
dure in the 5-, 10-, and 15-Gallon Pressure
Tanks manual. An agitator is recommended for
urethane applications utilizing a pressure pot.
Set the agitator to 25-50 rpm.
b. Calibration Check Assembly Only: Close the
calibration check assembly.
c. Close the base (A) air motor slider valve.
d. Open the base (A) main air slider valve.
e. Set the base (A) air motor regulators to 10 psi
(70 kPa, 0.7 bar).
f. Set the fluid regulator adjustment to 40 psi
(280 kPa, 2.8 bar).
g. Place the base (A) hose end into a waste con-
tainer.
To avoid personal injury or machine damage, adjust all
air regulators counter-clockwise prior to turning the
main air on.
To avoid personal injury or machine damage, do not
exceed 25 psi on the base (A) material until a steady
flow of material has been established.