1. Engage the trigger lock.
2. Install the static mixer or nozzle onto the dispense
applicator. See specific applicator manual for
details.
NOTE: Cutting more than two outlet steps on the static
mixer may increase the chance of the mixing elements
being pushed out of the static mixer.
NOTE: If using the mixer element kit 24T035, assemble
the sleeve onto the MD2 dispense applicator prior to fas-
tening the 1/4 NPT outlet adapter. Hand tighten the 1/4
NPT outlet adapter.
3. Turn the power on at the electrical enclosure.
4. Open the base (A) and catalyst (B) main air slider
valves.
5. Open the base (A) and catalyst (B) air motor slider
valves.
Do not operate machine without all covers and
shrouds in place.