Pressure Relief Procedure
46 3A2894F
Pressure Relief
Procedure
1. If electrical power is supplied to the machine,
perform Base Purge, page 44.
If electrical power is not supplied to the
machine, continue to the next step.
2. S100 and P100: Close the base (A) and catalyst (B)
air motor slider valves.
U100: Close the base (A) air motor slider valve and
the supply ball valve on the pressure pot. Bleed the
air from the pressure pot by opening the manual
bleed valve.
MD2:
a. Remove the static mixer.
b. Open the catalyst (B) ball valve located near the
dispense applicator.
c. Disengage the trigger lock.
d. Trigger the gun to relieve pressure into a waste
container.
e. Verify the pressure gauges display “0”.
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury from
pressurized fluid, such as skin injection, splashing
fluid and moving parts, follow the Pressure Relief
Procedure when you stop dispensing and before
cleaning, checking, or servicing the equipment.