7. Calibration Check Assembly Only: Dispense
material into a waste container at the calibration
check assembly to verify the V/P shown on the DM
is at the correct value.
NOTE: A restrictor pin for the catalyst (B) restrictor
housing may be required to obtain 5 psi (35 kPa,
0.3 bar) or above for the V/P shown on the DM.
8. Disengage the trigger lock.
9. Hold a metal part of the gun firmly to a grounded
metal pail. Trigger the gun until the Display Module
shows “OK”.
10. Place two separate containers on two separate
scales and zero the scales. These containers will be
used in step 11.
NOTE: Weight units of the scales are to be set as
grams.