User's Manual

Calibration Check
3A2894F 51
11. Dispense the chemicals into two separate contain-
ers.
MD2: Chemical will be dispensed through the appli-
cator.
Ultra-lite: Chemical will be dispensed through the
calibration check assembly.
12. Continue to dispense the chemical into the contain-
ers until a 400 gram shot has been dispensed.
NOTE: A value will be shown on the DM when a dis-
pense is complete. This is the value the machine was
running at based on the flow meter values.
13. Weigh both containers separately and calculate the
ratio (A/B) of the two chemicals.
14. Compare the ratio calculated from the weighed con-
tainers with the ratio shown on the DM.
15. If the ratio comparison is acceptable, acti-
vate on the DM or repeat steps 10 through 14
twice if more verification is required. Press to
clear all values if more than three samples are
required.
16. If the ratio comparison is unacceptable, perform
Calibrate the machine. page 38.