User's Manual
Setup
3A2960D 11
Setup
Entering SETUP MODE
1. Press both the UP and DOWN ARROW buttons
together for three seconds.
NOTE:
• If a button is not pushed for 1 minute, the controller
returns to the start of an OFF cycle.
• Setting changes are not stored unless programming
is completed and setup mode is exited normally by
pressing the ENTER button.
• A blinking dot below the HH, MM, SS, or ## indi-
cates the field currently being programmed.
Programming ON Duration
• on:Pr, on:CY or on:ti appears on the display identi-
fying the function you are programming (see below).
• The illuminated LED below the related symbol on
the controller label also indicates the function.
NOTE: Selection on:Pr, on:CY or on:ti designates
the way the pump run time is controlled:
• on:Pr = Pressure Control,
reaching a specific pressure
threshold measured by an
external pressure switch
• on:CY = Cycle Control, com-
pleting a specific number of
cycles of an external
prox/cycle switch
• on:ti = Time Control, a spe-
cific duration of time elapses
Pressure Control (on:Pr) ON Setup
1. Use the UP or DOWN ARROW
until on:Pr displays.
2. Press the ENTER button.
3. Pressure control is an ON / OFF
selection only. After you press the ENTER button,
the controller saves the Pressure Control informa-
tion and moves to setting Backup Time, page 12.
Cycle Control (on:CY) ON Setup
1. Use the UP or DOWN ARROW
until on:CY displays.
2. Press the ENTER button.
The first number displayed after the
on:CY is entered, blinks, indicating the device is ready
to program the number of cycles.
NOTE: The cycle entry is a 2-digit number. A leading
zero (0) must be entered in the first field if the number of
cycles is fewer than 10.
3. Program the cycles by pressing the UP or DOWN
ARROW to move up or down through the numbers
0-9.
4. When the correct first digit is displayed, press the
ENTER button.