User's Manual

Setup
12 3A2960D
The cursor automatically moves to the second number
field and flashes.
Use the UP or DOWN ARROW to scroll through the
numerals 0-9 until the desired number appears in the
second cycle number field.
5. Press the ENTER button. After you press the
ENTER button, the controller saves the Cycle Con-
trol information and moves to setting Backup Time,
page 12.
Time Control (on:ti) ON Setup
1. Use the UP or DOWN ARROW to
cycle through until on:ti displays.
2. Press ENTER.
3. To set the ON time use the UP or
DOWN ARROW to scroll through
the numerals 0-5 until the desired number appears
in the first Minutes (MM) field.
NOTE:
The MM field is a 2-digit number.
A leading zero (0) must be entered in the first
field if the number of minutes is fewer than 10.
The highest number that can be set for the MM
field value is 59.
4. Press the ENTER button.
The next MM number field to the right flashes, indicating
it is ready for programming.
5. Use the UP or DOWN ARROW to scroll through the
numerals 0-9 until the desired number appears in
the second MM number field.
6. Press the ENTER button.
The next number field to the right flashes indicating it is
ready to program the Seconds (SS) fields.
NOTE:
The Seconds (SS) field is a 2-digit number.
A leading zero (0) must be entered in the first
field if the number of seconds is fewer than 10.
The highest number that can be set for the SS
field value is 59.
7. Repeat steps 3 - 6 to set the SS fields.
8. Press the ENTER button. After you press the
ENTER button the controller automatically switches
to the OFF TIME SETUP MODE.
Backup Time
In both Cycle and Pressure Modes, a maximum run
Time (Backup Time) for the lubrication period must be
set up. If this Time expires before the lubrication is com-
pleted an alarm/warning is triggered and the pump
stops.
To determine the Backup Time, Graco recommends the
user verify the length of time it takes to complete a typi-
cal cycle and double that value.
Backup Time is setup after Cycle or Pressure Sensor
Setup is complete.
NOTE:
The LED below the clock in the ON field
lights, indicating the Backup Time is being
programmed.
BACKUP (ON) Time is set as minutes and seconds
(MM:SS) only.
The small flashing LED under the MM indicates you
are setting minutes.
The first field (left side of display) blinks indicating
the device is ready for you to begin programming.
Programming Backup Time
NOTE: When programming a time of less than 10 min-
utes you must program the leading zero in the first num-
ber field and press the ENTER button.