User's Manual

Setup
14 3A2960D
1. Use the UP or DOWN ARROW
until LL:02 displays. This will set
the controller up to use a "pad-
dle-style" low level algorithm (like
the Graco G3 grease units). To
ensure a low level condition has
been met in this mode, 10 consec-
utive low level triggers must be
detected. If a low level trigger is
not detected in 30 seconds of run
mode, the count is reset to zero.
2. Press the ENTER button.
NOTE: When the user exits SETUP
MODE:
An alarm sounds briefly and LED lights indicating
the new programming settings and OFF TIME infor-
mation are saved.
The display shows the revision level.
The controller goes to the beginning of a PUMP
OFF Cycle.
Operation
Run Mode
The controller is in Run Mode providing the following cir-
cumstances are present:
The controller is not in SETUP MODE.
An Alarm is not active.
Pressure Mode: Pump ON
The display indicates the amount of backup time
remaining (see Pressure Mode (on:Pr) ON setup, page
12).
The Pressure ON LED illuminates and the pump
output is enabled as long as the system is in the
Pump ON state.
If the pressure switch input is activated before the
Backup Pump On Time expires, the system
switches to a Pump OFF state.
If the pressure switch is NOT activated before the
Backup Pump On Time expires the system faults,
goes to the Pump OFF state and pauses until the
alarm is cleared.
Pump ON time is shown in MM:SS (minutes:sec-
onds)
Pressure Mode: Pump OFF
The display indicates the amount of time remaining in
the pump OFF cycle, counting down the Pump OFF time
value (see Programming OFF Time Duration, page 12).
The pump output is disabled during the Pump OFF
time.
The Time OFF LED is illuminated as long as the
system is in the Pump OFF state.
Pump OFF time is shown in HH:MM (hours:minutes)
or MM:SS if the time remaining is less than an hour.