User's Manual
Technical Data
3A2960D 19
Technical Data
Input Contact
Power Source DC 9 - 30 VDC
Power Consumption 1 Watt
Cycle/Pressure Control Input (optional) 9 - 30 VDC, Normally open Pressure or cycle switch
Lubrication level (optional) Normally open level switch, closes upon low level
Outputs
Pump control Pump Control Voltage = Power Source
Voltage Pump Control Voltage = Power Source
Max Switching Voltage 30 VDC
Max Switching Current 9A (DC)
Min Switching Current 100 mA (DC)
Alarm, normally open
Voltage Alarm = Power Source
Max Switching Voltage 30 VDC
Max Switching Current 2A (DC)
Protection grade
IP54 for indoors and vehicle cab use
Alarm Sound Pressure Level
75 dB
Enclosure Material
ABS
Membrane Material
Polyester
Maximum Humidity
90% RH (non-condensing)
Operating temperature range - 40°F to 176°F (- 40°C to 80°C)
Storage Temperature - 40°F to 176°F (- 40°C to 80°C)