User's Manual

Installation
3A2960D 5
Installing the Lubrication
Controller
1. Select a flat surface to install the Lubrication Con-
troller. Drill mounting holes. Refer to Mounting Hole
Layout Provided in the Technical Data section of this
manual, page 20.
2. Align junction box with predrilled holes (F
IG. 3, (a).
Use two screws (not provided) to secure junction
box to mounting surface.
System Configuration and
Wiring
The System Configuration Diagrams (FIG. 4 - FIG. 6),
Sensor Wiring Diagrams (F
IG. 8 - FIG. 9) and Wiring Dia-
grams (F
IG. 7) on the following pages, show typical
Injector, Series Progressive and Dual Line lubrication
system configurations.
Refer to Table 1, 2 and 3 to determine the Required Sys-
tem Configuration, Sensor Configuration and Wiring
Diagram to use to setup your system.
Table 1: System Configurations
Table 2: Sensor Wiring Configurations
Table 3: Modes of Operation
AUTOMATIC SYSTEM ACTIVATION HAZARD
Unexpected activation of the system could result in seri-
ous injury, including skin injection and amputation.
This device has an automatic timer that activates the
pump lubrication system when power is connected or
when exiting the programming function. Before you
install or remove the Lubrication Controller from the
system, disconnect and isolate all power supplies and
relieve all pressure.
FIG. 3
a
a
System Figure Page
Injector 4 6
Series Progressive 5 7
Dual Line 6 8
Sensor Figure Page
Dry Contact 7 10
Source Switch 8 10
Mode Power Figure Page
Time ON/Time OFF DC 9 9
Cycle ON or Pressure
ON/Time OFF
DC 9 9
Low Level Switch
99