Repair
3A6884B 37
Transducer Replacement
Tools Required: 15/16 in. wrench.
Remove Transducer
1. Perform Pressure Relief Procedure
page 10 and disconnect power to the
TSP power pack.
2. Lift connector locking tab on transducer
electrical connector.
3. Unplug electrical connector from
transducer.
4. Use 15/16 in. wrench to remove
transducer from the manifold.
Install Transducer
1. Apply sealant to transducer threads.
2. Start threading transducer into the
manifold.
3. Using a 15/16 in. socket, tighten
transducer to 50-55 ft-lbs (68.8-75.6
N•m).
4. Plug electrical connector into the
transducer.
5. Verify proper operation and inspect for
leaks. If leaks are found, stop unit and
re-torque transducer.
6. Perform Calibration Procedure page
28.