LF1030 HYDRAULIC PATIENT LIFT LF1040 ELECTRIC PATIENT LIFT USER MANUAL LF1030-INS-LAB-RevB10 © 2010 GF Health Products, Inc. Read this manual before operating your Patient Lift. Save this manual for future use. The most current version of this manual can be found online at www.grahamfield.
CONTENTS 1 INTRODUCTION............................................................................................................................... 3 2 SAFETY PRECAUTIONS................................................................................................................. 4 WARNINGS................................................................................................................................. 4 3 FEATURES.........................................................................
1 INTRODUCTION Congratulations on your purchase of a Lumex patient lift. The following pages will provide you with important safety and operating instructions on the use of patient lifts, slings, and accessories, as well as maintenance and warranty information. Read this manual carefully before operating your patient lift and refer to it as often as needed.
2 SAFETY PRECAUTIONS IMPORTANT: Before using patient lift, please read and adhere to the following safety precautions and warnings. Failure to do so could result in serious injury or damage to your patient lift. Always consult your healthcare professional to determine safe methods most suitable for your individual abilities. Protect yourself, your attendant and patient lift by having it serviced regularly.
WARNING: Unauthorized modification of your patient lift or the use of non-Lumex replacement parts may change the structure of the lift and could create a hazardous condition, which may result in serious injury and will void the warranty. WARNING: LF1030 Hydraulic Patient Lift only: The hydraulic pump is sealed at the factory. If service is required, the unit must be returned to the factory for repair.
3 FEATURES Battery, battery charger, & control box (LF1040 Electric Patient Lift only) Boom Actuator (LF1040 Electric Patient Lift only) 6-point spreader bar (suspension) LF1040 Electric Patient Lift Mast Hydraulic pump (LF1030 Hydraulic Patient Lift only) See above left for LF1040 Electric Patient Lift components Push handle Base adjustment handle Locking casters Adjustable base LF1030 Hydraulic Patient Lift LF1040 Electric Patient Lift (unless otherwise specified, callout applies to both lifts) L
4 HANDLING PROCEDURES SHIPPING AND TRANSPORTATION INSTRUCTIONS If the patient lift is to be reshipped by common carrier, it should be packed in the same carton/s in which it was received (the LF1030 is shipped in one carton; the LF1040 motor may be packaged separately from the frame). Unpacking 1. Check for any obvious damage to the carton or its contents. If damage is evident, notify the carrier or your authorized Lumex Dealer. 2. Remove all loose packing from the carton. 3.
5 ASSEMBLY INSTRUCTIONS The LF1030 patient lift is packed in one carton. The LF1040 motor may be in a separate carton. Components are shown in illustration below and called out in list below illustration. COMPONENTS 3 4 7 6 5 1 8 2 LF1040 * LF1030 hydraulic patient lift components Item Qty 1 1 Description Mast/Boom/Pump assembly (LF1030) 1 Mast/Boom/Actuator assembly (LF1040) * Note: Actuator, Charger, Pendant and mounting items are packaged separately on LF1040.
ASSEMBLY 1. Remove the locking pin from the mast sleeve located on the rear of the base. remove locking pin 2. Install the L-inserts in the base. install L-inserts 3. With the boom pointed in the same direction as the base legs, insert the mast into the sleeve. 4. Insert the locking pin through the holes of the sleeve and mast, and attach the locking cable to the end of the pin. install mast and locking pin 5. Screw the two mast attachment bolts into the holes in the sleeve of the base.
6. Screw the push handles into the mast and tighten the nuts. install push handles 7. Insert spreader bar attachment rod into spreader bar. Insert spreader bar rod into the U-bracket at the end of the boom. Align holes. Insert spreader bar attachment bolt and tighten. install spreader bar 8. Install the base adjustment handle in the socket located behind the mast sleeve on the base.
Note: Steps 10-13 apply to LF1040 Electric Patient Lift only. Control box Cap screw 10. Attach control box using 5mm cap screws as shown at right. attach control box 11. Attach battery charger using 5mm cap screws as shown at right. 12. Clip battery onto unit. 13. See following Electrical connections section.
Charging the battery with lift-mounted battery charger: With control box, battery charger, and battery assembled, insert the battery charger plug into a standard 110V receptacle. A green light signifying power and a yellow light signifying that the battery is charging will illuminate on the battery charger. When the battery is fully charged, the yellow light will shut off. The lift is now ready for use. Note: The patient lift will not operate during lift-mounted battery charging.
6 OPERATING INSTRUCTIONS LIFTING THE PATIENT WARNING: Do not attempt to transfer a patient without prior approval of the patient’s healthcare professional and without having read the instructions and practiced using the patient lift. WARNING: Use special care for those patients who cannot cooperate while being lifted. WARNING: Ensure all bolts, hooks, and loops are securely fastened. WARNING: Use only Lumex slings with Lumex patient lifts.
Lifting the patient from the floor 1. Position the patient lift behind the patient, placing a pillow over the base to protect and support the patient’s head and neck. Place the patient's head carefully on the base. The patient lift should be positioned with the spreader bar centered over the patient. 2. Lower the spreader bar. Attach the sling to the spreader bar hooks. 3. Lift the patient up above the floor. Position the patient in the sling by pulling the handle on the back of the sling.
Removing the sling Gently pull the leg sections to the side, out from under the patient’s thighs. Standing by the patient’s side, lean the patient forward while supporting the patient with one hand. Pull the sling up from behind the patient’s back and position the patient in the chair. WARNING: Pulling sharply on the sling may cause the patient to fall forward, resulting in personal injury. Always support the patient by keeping one arm around the patient’s shoulders when placing or removing the sling.
7 CARE AND MAINTENANCE Proper care and maintenance are essential to keeping your Lumex patient lift in a safe operating condition. In addition to inspecting the unit before each use, periodic maintenance checks should be done. We further recommend that this unit be serviced at least once annually by an authorized dealer. WARNING: It is extremely important that the patient lift be inspected before each use. Ensure that all hardware and accessories are secure and that the actuator is functioning properly.
CLEANING Regular cleaning is recommended. A soft cloth, dampened with water and a mild NON-ABRASIVE detergent (household cleaner, soapy water, or hospital grade disinfectant) is all that is needed to clean your patient lift. Automobile wax or furniture polish will help maintain the finish over a long period of time. CAUTION: DO NOT wash under water pressure or steam clean.
Installation of New Pump mast Note: The hardware for attaching the Hydraulic Pump (GF #1010S005) to the LF1030 mast and boom comes with the lift frame. 1. Attach the bottom of the new hydraulic pump to the lower mast bracket with the pressure knob and pump lever toward the bottom of the pump, as shown at near right, and the “FRONT” label toward you, as shown at far right. Use a hex bolt, washers, and hex nut to secure pump to mast. Use two 9/16" wrenches to tighten. 2.
MAINTENANCE SCHEDULE Note: Only qualified persons should service and repair your Lumex patient lift. Regular maintenance of your patient lift is necessary to ensure continuing proper and safe operation.
8 TROUBLESHOOTING WARNING: If you experience a problem with your lift and are unable to service it yourself, contact your Lumex dealer. LF1030 HYDRAULIC PATIENT LIFT SYMPTOM POSSIBLE CAUSE ACTION Patient lift does not go up or down Air in the cylinder Bleed the cylinder by turning the release knob and push down on the mast. Pump up the lift again and turn the release knob again.
10 LIMITED WARRANTY GF Health Products Inc. warrants this product to be free from manufacturing defects in material and workmanship for its period of warranty that is in accordance with industry standards. This warranty is extended only to the original purchaser/consumer or dealer/non-consumer of this new product and to no other purchaser or transferee. GF Health Products, Inc.
THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES AND IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, AND SHALL NOT EXTEND BEYOND THE DURATION OF THE EXPRESS WARRANTY PROVIDED HEREIN, AND THE REMEDY FOR VIOLATIONS OF ANY IMPLIED WARRANTY SHALL BE LIMITED TO THE REPAIR, REPLACEMENT, CREDIT AND/OR REFUND OF THE DEFECTIVE PRODUCT OR PART PURSUANT TO THE TERMS CONTAINED HEREIN. GF HEALTH PRODUCTS, INC.
11 INDEX A Assembly instructions 8 B Battery care 16 Before each use 16 C Care and maintenance 16 Care of slings 17 CAUTION statement, significance 3 Charging the battery (LF1040 only) 11 Checking for damage and wear 17 Cleaning 17 Components 8 E Electrical connections (LF1040 only) 11 Emergency procedures (LF1040 only) 12 F Features 6 H Handling Procedures 7 Hydraulic Pump 1010S005, Installation (LF1030 only) 17 S Safety precautions 4 Safety statements, significance of 3 Shipping and transport
USA Company Headquarters: GF Health Products, Inc. 2935 Northeast Parkway Atlanta, Georgia 30360 USA tel: 800-347-5678, 770-368-4700 fax: 800-726-0601, 678-291-3232 Made in Taiwan www.grahamfield.