User guide

3. Installation
PNEG-1324 72', 75', 78', 90' and 105' Cor-Lok and Cut-Lok Flooring 19
Installation Instructions
1. When a splice is needed, plank length A as described in the floor manual should be installed
alongside plank length B.
2. The under-splice should then be installed under the split of plank A and B. The splice should extend
3" under each plank. The splice should be screwed in place as shown in Figure 3C on Page 18.
3. This process will be repeated for all plank locations requiring a splice.
Figure 3D