User Manual
6. 345 Cut-Lok/20 Gauge Cor-Lok Floors for Non-GSI Bins
16 PNEG-529 Cor-Lok and Cut-Lok Flooring for Non-GSI Bin Diameter
Grandstand Support Requirements for Above Floors
Spacings and quantities of supports are shown below.
Diameter 6 Rings (16' 8 Eave) 7 Rings (19' 5 Eave) 8 Rings (22' 2 Eave)
Nom. Act. Spacing # of Supports Spacing # of Supports Spacing # of Supports
19' (18' 7) 52/26 136 50/25 140 48/24 144
22' (21' 8) 52/26 177 48/24 188 46/23 194
25' (24' 9) 50/25 238 48/24 245 44/22 262
28' (27' 10) 50/25 300 46/23 320 44/22 330
31' (30' 11) 50/25 370 46/23 390 44/22 410
34' (34' 0) 48/24 460 46/23 480 44/22 490
38' (37' 1) 48/24 550 46/23 560 42/21 610
41' (40' 2) 48/24 640 44/22 680 42/21 710
44' (43' 3) 46/23 770 44/22 790 42/21 820
50' (49' 5) 46/23 1000 42/21 1070 42/21 1070