VERSION: 1.06
1) Fixed dryer so the grain hi limit occurs at 20 F above the grain temp setpoint.
2) Made timeout on the open/close of the actuator 20 seconds instead of 15 seconds. This
extra time was added to compensate for the weaker batteries taking longer to close the
chutes.
VERSION: 1.05
1) Made the out of grain timer active.
VERSION: 1.04
1) The application of 12v to terminal number j1-20 will shutdown the dryer and give an
indication that the bin is full due to the high level of static pressure within. BIN AIR PRES
SURE LIM will be displayed on screens top line until the user corrects the problem.
2) Corrected the hour meter problem.
3) Changed how the dry timer is displayed: Now when the dry timer goes to zero it will begin
counting upward at the user set time as long as the dryer remains in temp hold.
VERSION: 1.03
1) Added software to allow the aeration fan to continue running even if there was a dryer shut
down. The aeration fan BYPASS mode must be selected under setup.
VERSION: 1.02
1) The Bin high limit rotary switch is monitored in both states to insure that a switch failure has not
taken place. If both switches are in the same state a switch failure is reported.
Software Changes
Significant Software Changes
(Software version number is displayed at all units on power-up)