5. Required Tools and Critical Tool Characteristics
26 PNEG-1708 GSI Modular Tower Dryer
5. Laser transit level tool: After placing the unload/base module on the concrete foundation and
establishing its proper orientation to other equipment it must be leveled. GSI strongly recommends
using a Laser transit leveling tool to level the unit. (See Figure 5E.) If a Laser transit is not
available, a carpenter’s level may be used.
It is critical to establish the base/unload module as level. Even a minor deviation at this level
will be a significantly greater deviation at the top section. Therefore, pay particular attention to
confirming the levelness of the base/unload module. Shims are available to assist with leveling the
base/unload module. (See Figure 5F.)
Figure 5E Laser Transit Level
Figure 5F