Competitor/Dri-Tek Control Panel Operation Manual PNEG-1758 Date: 07-21-10 PNEG-1758
PNEG-1758 Competitor/Dri-Tek Control Panel
Table of Contents Contents Chapter 1 Competitor/Dri-Tek Control Panel ......................................................................................................4 Dryer Control Panel Featuring the Series 2000 Control System ........................................................... 5 Special Features ................................................................................................................................. 10 Safety Circuit Shutdown Messages ...............................
MARCHE ARRÊT AUTO ARRÊT OFF MARCHE ON LUMIÈRE EXTÉRIEURE OUTSIDE LIGHT ON OFF GROUPE ETAGÉ STAGED BATCH FLOT CONTINU CONT. FLOW CONT.
1. Competitor/Dri-Tek Control Panel Dryer Control Panel Featuring the Series 2000 Control System The control panel provides easy access to gauges and controls. The Competitor Series 2000 Control System is a computerized control system that gives instant information regarding dryer operation. Moisture Control (Temperature Based) The Series 2000 dryer has a built in moisture control. It controls the moisture level of discharged grain by sensing grain column temperature.
1. Competitor/Dri-Tek Control Panel Unload Switch The Unload switch turns the metering rolls and discharge auger ON or OFF and selects the operation of the metering rolls.
1. Competitor/Dri-Tek Control Panel Dryer Power Stop Switch This switch stops all dryer functions. If an automatic dryer shutdown occurs, first determine and correct the cause of the shutdown. Press the Dryer Power Stop button to reset the dryer before restarting. Series 2000 Control System The Series 2000 System controls all timing functions and safety circuit checks. It is designed to simplify dryer operation by providing messages and warnings on its Liquid Crystal Display (LCD).
1. Competitor/Dri-Tek Control Panel Setting the Dry, Cool, Unload and Out of Grain Timers These switches are used to set the drying cycle times in the staged batch drying mode only. The Drying Mode switch must be in the staged batch position. Out of grain sets the length of time the dryer will run before shutting down when the Load switch is in the AUTO position. To change the setting of these timers, follow these instructions: 1.
1. Competitor/Dri-Tek Control Panel Setting the Moisture Control and Plenum Setpoint 1. Press the Program (Temperatures) button until the carrot is under the temperature setting to be changed. 2. Use the UP and DOWN arrow keys to change from the present temperature to the new one. The new time is automatically entered. 3. Keep pressing the Program (Temperatures) button until the carrot disappears or press the Mode Select button once to exit.
1. Competitor/Dri-Tek Control Panel Special Features Dual Batch Drying Temperature Mode To greatly improve quality in batch mode, reduce the plenum temperature at the end of the drying cycle. This will reduce peak temperature that the grain on the inside of the column attains and thereby reduce over-drying.
1. Competitor/Dri-Tek Control Panel Loss of Flame The flame sensor failed to detect a burner flame, indicating that the burner has failed to light. There is a problem with the flame sensing circuitry or the dryer is not getting burner fuel. The burner switch light will be lit any time flame has been sensed by the burner controls.
1.
1.
NOTES 14 PNEG-1758 Competitor/Dri-Tek Control Panel
2. Warranty GSI Group, LLC Limited Warranty The GSI Group, LLC (“GSI”) warrants products which it manufactures to be free of defects in materials and workmanship under normal usage and conditions for a period of 12 months after sale to the original end-user or if a foreign sale, 14 months from arrival at port of discharge, whichever is earlier.
This equipment shall be installed in accordance with the current installation codes and applicable regulations which should be carefully followed in all cases. Authorities having jurisdiction should be consulted before installations are made. 1004 E. Illinois St. Assumption, IL 62510-0020 Phone: 1-217-226-4421 Fax: 1-217-226-4420 www.gsiag.