User's Manual

14 / 15
GM9K SERIES (INCLUDE GM9K1 / GM9K2 / GM9K3) USER MANUAL - FOR OEM USE ONLY
H13
[GRAND MATE] Version: D05.0 at Dec 19
th
, 2019
START
Safety check of prior
to ignition
Safety check of
combustion
Pass
Sparking Error
(LOCK-OUT-A)
Red LED Flash 2 time
Error Code I01
Igniting Error
(LOCK-OUT-A)
Red LED Flash 3 time
Error Code I02
Error
Re-ignition Excess
(LOCK-OUT-A)
Red LED Flash 5 time
Error Code I03
Pilot Valve Error
(LOCK-OUT-A)
Red LED Flash 6 time
Error Code I07
Main Valve Error
(LOCK-OUT-A)
Red LED Flash 7 time
Error Code I08
Error
Ignition process
completed
Pass
Press Remote handset
ON button
System in
Remote Mode
Flame detected
prior to ignition
Beep twice
Countdown
finish?
15 sec system wait time for
thermocouple cool down
System not accept any
RF control signal until
countdown finish
N
Press remote handset
ON button
Safety check of prior
to ignition
Y
A
No flame exist
Flame exist
A
Safety check of
sparking
Pass
Trial for Ignition
(LOCK-OUT-A)
Red LED Flash 4 time
Error Code I04
Error
Ignition Success
Beep once
Sparking activated
Sparking Error
(LOCK-OUT-A)
Red LED Flash 2 time
Error Code I01
Safety check of
flame detection
Pilot valve
energized
Flame exist
No flame exist
Main valve
energized
Igniting Error
(LOCK-OUT-A)
Red LED Flash 3 time
Error Code I02
Figure 11: Remote mode operating sequence part 2 of 2