Full Product Manual

GrandPrix Two-Post Lifts 61 P/N 5900209Rev. D3 Feb. 2020
Maintenance
DANGER Before performing any maintenance on your Lift, make sure it is completely
disconnected from power. The Lift uses electrical energy; if your organization has
Lockout/Tagout policies, make sure to implement them before performing any
maintenance. If you come into contact with high voltage/current, you could be
injured or killed.
To maintain your Lift:
Daily: Keep the Lift clean. Wipe up any spills, clean any dirt.
Daily: Make a visual inspection of all moving parts and check for damage or excessive wear.
Replace any damaged or worn parts before using the Lift.
DANGER Do not use the Lift if the cables are damaged or extremely worn. If a Vehicle is
raised when you notice the damage or extreme wear, very carefully lower the
Vehicle to the ground. When the Lift is on the ground, remove it from service,
disconnect it from power, and make arrangements to get it fixed.
Daily: Make sure Safety Locks are in good operating condition. Do not use your Lift if the Safety
Locks are damaged or excessively worn.
Weekly: Check the controls to make sure they are functioning normally.
Weekly: Check all labels on the Lift. Replace them if they are illegible or missing.
Monthly: Lubricate the Posts and the Sheave Pins. We recommend using white lithium or light
axle grease.
Monthly: Check the Hydraulic Fluid levels in the reservoir on the Power Unit. Refill if low.
Only measure fluid levels when the Lift is fully lowered. Otherwise, some of the fluid will be in the
hoses and the cylinder, and thus throw off your fullor lowassessment.
Monthly: Check cable connections, bolts, and pins for proper mounting and torque.
Monthly: Check arm adjusting locks for proper operation.
Monthly: Make sure all pivot arm pins are properly secure.
Every two months: Check all Anchor Bolts to make sure they are correctly torqued. If they are
not, torque them.
Every three months: Check the lubrication of the Wire Rope.
Every three to five years or as needed. Carefully check the Lifting Cables every three to five
years, or immediately if there are signs of damage or extreme wear. See Wire Rope Inspection
and Maintenance for additional information.
WARNING: Do not operate your Lift if you find maintenance issues; instead, remove it from
service, then contact your dealer, visit bendpak.com/support, email
techsupport@bendpak.com, or call (800) 253-2363.