HDD DETECTION
GVR3550/GVR3552 provides S.M.A.R.T. (Self-Monitoring, Analysis and Reporting Technology) detection
and bad sector detection. Users could view HDD running status via HDD detection.
S.M.A.R.T detection provides detection like HDD heads, temperature, material of disk surface and
forecasting the underlying problems of HDD that may occur in time.
S.M.A.R.T detection page is as shown in Figure 78 below.
Figure 78 S.M.A.R.T. Detection Page
Table 37 HDD S.M.A.R.T Detection Parameters Explanation
Parameter Explanation
Continue Use the
HDD after Self-test
Failed
Continue to use the HDD if self-test failed in the process of S.M.A.R.T. Detection.
Note: Once enabled, it may cause HDD error, please be careful!
HDD No.
HDD Number 1-4 will be allocated in sequence after HDD installation, the number
will not be changed in the subsequent use.
Detection Type
Set S.M.A.R.T. detection type: Short, Long, Conveyance.
Start
Click the button to start S.M.A.R.T. detection.
HDD Temperature
Display HDD temperature S.M.A.R.T detection detected.
Usage Time
Display total HDD usage time S.M.A.R.T detection detected.
Detection Status
S.M.A.R.T detection results.
Evaluation Result
S.M.A.R.T detection results on HDD status.
Overall Evaluation
Display overall HDD status after detection.