User's Manual

Firmware Version 1.0.0.32 UCM6102/6104/6108/6116 USER MANUAL Page 46 of 110
hangup polarity switch. (default: 600ms)",
RX Gain
Gain for the receive channel of analog FXO port. Range: -13.5 (dB) to +
12.0 (dB).
TX Gain
Gain for the transmit channel of analog FXO port. Range: -13.5 (dB) to +
12.0 (dB).
Ring Timeout
unit: milisecond . Trunk (FXO) devices must have a timeout to determine
if there was a hangup before the line was answered. This value can be
tweaked to shorten how long it takes before asterisk considers a
non-ringing line to have hungup.",
Use CallerID
Enabling this option enabled Caller ID detection
Caller ID Start
This options allows one to define the start of a Caller ID signal: Ring, to
start when a ring is received, or Polarity, to start when a polarity reversal
is started
Current Disconnect Threshold
(ms)
This is the periodic time in milliseconds that the PBX will use to check on
a voltage drop in the line. Default setting is 200ms.
CID Signalling
This option defines the type of Caller ID signalling to use: bell (bell202
as used in the United States), v23 (as used in the UK), v23_jp (as used
in Japan), or dtmf (as used in Denmark, Sweden, and Holland)."
Tone Country
Select country for tone settings. You can also select Custom and set the
values manually.
Busy Tone
Syntax:
f1=val[@level][,f2=val[@level]],c=on1/off1[-on2/off2[-on3/off3]];
Frequencies are in Hz and cadence on and off are in ms.
Frequencies Range: [0, 4000)
Busy Level Range: (-300, 0)
Cadence Range: [0, 16383].
Select Tone Country "Custom" to edit manually.
Default value:
f1=480,f2=620,c=250/250
Congestion Tone
Syntax:
f1=val[@level][,f2=val[@level]],c=on1/off1[-on2/off2[-on3/off3]];
Frequencies are in Hz and cadence on and off are in ms.
Frequencies Range: [0, 4000)
Busy Level Range: (-300, 0)
Cadence Range: [0, 16383].
Select Tone Country "Custom" to edit manually.