Grandstream Networks, Inc.
GXV3615WP_HD IP Camera Series Safety Instructions These instructions are intended to assist users with the operation of the GXV3615WP_HD and also to instruct on how to avoid dangerous situations or damage to the device. Warnings: Serious injury or death may be caused if any of the warnings below are neglected. Cautions: Injury or damage to the equipment may occur if any of the following caution messages are neglected. Warnings Follow these safeguards to prevent serious injury or death.
GXV3615WP_HD IP Camera Series Contents Welcome .........................................................................................................................................................4 Package Contents............................................................................................................................................5 Product Overview ......................................................................................................................................
GXV3615WP_HD IP Camera Series Welcome The GXV3615WP_HD Series is a next generation IP camera for remote monitoring and surveillance over your LAN or internet. The GXV3615WP_HD Series combines best in class IP video technology and SIP protocols for a robust IP surveillance solution. The product features H.264 video streams with up to 30 frames per second in full D1, delivering rich image clarity at rapid transmission rates.
GXV3615WP_HD IP Camera Series Package Contents Items in the package: • • • • • GXV3615WP_HD /GXV3615W_HD / GXV3615P_HD/ GXV3615_HD IP Camera 12V DC power Adapter Mount Stand Ethernet Cable Quick installation guide Product Overview GXV3615WP_HD series includes 4 models: GXV3615WP_HD /GXV3615W_HD / GXV3615P_HD/ GXV3615_HD GXV3615WP_HD Series Overview Firmware 1.0.4.8 Grandstream Networks, Inc.
GXV3615WP_HD IP Camera Series GXV3615WP_HD Series Front Panel Speaker– GXV3615WP_HD built-in speaker Status Indicator – Red when power up / Green when ready. Microphone– GXV3615WP_HD built-in microphone GXV3615WP_HD Series Back Panel NETWORK – 10/100 Switch LAN port for connecting to Ethernet. The indicator will be steady for connection and flashing for network activity. DC 12V – 12V DC power jack; UL Certified.
GXV3615WP_HD IP Camera Series GXV3615WP_HD Series Key Features The table below lists the key features the GXV3615WP_HD Series. Features GXV3615WP_ HD Image Sensor 1/3”, CMOS, 1600H x 1200V pixel resolution, exceptionally low noise levels and low-light sensitivity achieve superior resolution at CCD image quality Lens Type 1/3”, M12, f=4.20mm, F1.5, FOV=64° Minimum Illumination 0.05Lux Video Compression H.
GXV3615WP_HD IP Camera Series Snapshots Trigger upon events, send via email/FTP Network Protocol TCP/UDP/IP, RTP/RTCP, RTSP, DHCP, DDNS, HTTP, HTTPS, SMTP, FTP, NTP Network Port 10M/100M auto-sensing, RJ45 Multi-streaming-rate for Preview and Recording Yes Security HTTPS, password Power over Ethernet (PoE) Standard,IEEE 802.3afClass 3 N/A Standard, IEEE 802.3af Class 3 N/A Wi-Fi (802.11b/g/n) N/A Yes N/A N/A SIP/VoIP Support Yes, Voice & Video-over-IP Weight 0.
GXV3615WP_HD IP Camera Series Installation Guide Minimum Recommended System Requirement • • • • Windows 2000 Server Professional, Windows XP, Windows Vista. CPU: Intel Pentium 4 or higher, 2 GHz. RAM: 1 GB (4 GB recommended for larger systems). Support for DirectX 8.0 and above. . Connect your GXV3615WP_HD Series Using the Power adapter as power supply • • • Connect an RJ-45 cable to the NETWORK port of the GXV3615WP_HD. Connect the other end of the RJ-45 cable to your network or PC.
GXV3615WP_HD IP Camera Series Configuring the GXV3615WP_HD Series via Web Browser The GXV3615WP_HD’s embedded Web server responds to HTTP/HTTPS GET/POST requests. Embedded HTML pages allow you to configure your IP camera through Microsoft Internet Explorer. Access GXV3615WP_HD Series Web Configuration Menu Connect the Camera to DHCP server. 1. Navigate your browser to: http://www.grandstream.com/support/gxv_series_surveillance/general/resources/gs_ search.zip 2.
GXV3615WP_HD IP Camera Series Connect to the Camera using Static IP. If the camera does not get response from DHCP server after 3 minutes, it can be accessed by the default IP 192.168.1.168. 1. Connect your PC to the same network as the GXV3615WP_HD. 2. Configure the IP address of your PC to: 192.168.1.XXX (1
GXV3615WP_HD IP Camera Series GXV3615WP_HD Series Home Web Page Figure1: Home web page of GXV3615WP_HD Items on GXV3615WP_HD Home Page 1 Motion Detection 2 Alarm Event 3 4 5 6 7 Language Control Console ZOOM FOCUS Default 8 9 10 11 12 SPEED BRIGHTNESS CONTRAST SATURATION View Size 13 Play If the motion detection alarm is triggered, the indicator will flash red. Click on the indicator to turn off the alarm. If an alarm event is triggered, the indicator will flash red.
GXV3615WP_HD IP Camera Series 14 Capture 15 Record 16 17 18 19 Sound Off/On Talk Playback Config Captures the image displayed and saves it to C:\GS_Capture (default directory). Records the video and saves it to C:\GS_Record (default directory). Toggles the sound On or Off. Establishes two-way audio. Replays the saved video. Configures the Save Location for captured images and recorded videos. GXV3615WP_HD Series System Page This page allows you to configure the system settings on GXV3615WP_HD.
GXV3615WP_HD IP Camera Series Grandstream network cameras or digit video cameras in the same subnet. GXV3615WP_HD Series Video & Audio Page On Screen Display (OSD) Settings OSD Time/ Text – The time stamp and channel name displayed on the screen. Video Settings Preferred Video Codec – The GXV3615WP_HD supports the H.264 video codec. Resolution – The higher the resolution is, the better the video quality is, and higher bandwidth is required.
GXV3615WP_HD IP Camera Series to show the incremental difference between each frame. I-frames are used to help keep the video looking normal. When intervals are shorter, the video quality is higher but uses more bandwidth. NOTE: The users might need to configure the Primary Stream and Secondary Stream properly.
GXV3615WP_HD IP Camera Series fields are set to zero by default. Static IP addresses are recommended for the GXV3615WP_HD DNS Configuration There are two methods of DNS configuration on the GXV3615WP_HD: 1. The GXV3615WP_HD can obtain the DNS server automatically 2. Users can configure their own preferred DNS server HTTP Port The GXV3615WP_HD supports user configured http ports. If the HTTP port is changed, the port number is needed to access the web GUI, for instance: http://192.168.1.168:8080.
GXV3615WP_HD IP Camera Series 1. Apply for a domain name from your service provider. 2. Login to the web configuration page, click Basic Settings > DDNS. 3. Enter the required information DDNS Active – If you want to use DDNS, please set this field to “Enabled” . DDNS ISP Type – Select your DDNS ISP Type. Self-Define DDNS Address – Self-define the DDNS server instead of using DDNS ISP Type. Site Name – The DDNS name for your device.
GXV3615WP_HD IP Camera Series 5. network environments. If the system detects a symmetric NAT, STUN will not work. ONLY outbound proxies can provide a solution for a symmetric NAT. SIP User ID – User account information provided by your service provider (ITSP); this is either an actual phone number or is formatted like one. Authenticate ID – The SIP service subscriber’s Authenticate ID used for authentication. It can be identical to or different from the SIP User ID.
GXV3615WP_HD IP Camera Series Available phone numbers NOTE: With current firmware, only the first phone number in the list will be called when an alarm is triggered. GXV3615WP_HD Series Status Page System Statistics System Statistics lists hardware and software information, for example, the part number, the software version, about the GXV3615WP_HD. Hardware Version – This field contains the product’s hardware information. Part Number – This field contains the product part number information.
GXV3615WP_HD IP Camera Series DDNS Status – This field shows the status of DDNS. Camera Type This section shows the Lens information of GXV3615WP_HD. The Lens type information contains the brand name, the size of image sensor, the resolution and so on. GXV3615WP_HD Series User Management Page All current users will be list in the User List section of this page. You can also add and remove users here. Existing User Name –The field lists all of the current users.
GXV3615WP_HD IP Camera Series Firmware Upgrade and Provisioning Items Upgrade via – This field lets you choose the firmware upgrade method. The GXV3615WP_HD supports HTTP, HTTPS and TFTP. Firmware Server Path – The IP address or domain name of the firmware server (the location of the firmware files) . Automatic Upgrade Interval – Enter the frequency (in minutes) in which the HTTP/HTTPS/TFTP server will be checked for new firmware upgrades or configuration changes.
GXV3615WP_HD IP Camera Series 465, which is for SMTP with an encrypted connection. From E-Mail Address – The email address that sends out the alarm email(s). To E-Mail Address – The email addresses that the alarm email(s) will be sent to. You can have up to 3 emails configured. User Name/ Password – The user name and password required to log in to your SMTP server, for example, 123@gmail.com/123. SSL – Checked if the SMTP server requires a secure connection.
GXV3615WP_HD IP Camera Series Setup Motion Detection Monitored Area Enable Motion Detection – If this option is selected, motion detection will be enabled. If something/somebody moves in the motion detection region, an alarm will be triggered. Show Motion Detection Regions – If this option is selected, the motion detection regions will be displayed on the screen with a white border.
GXV3615WP_HD IP Camera Series GXV3615WP_HD allows multiple alarm actions. Configure Motion Detection Time Schedule This section allows you to configure the time during which the GXV3615WP_HD will monitor the motion detection. The GXV3615WP_HD not only can monitor your settings but also can take actions when the alarm is triggered. Monitored region Dropdown list for date Available time schedules GXV3615WP_HD Series System Log This page is used to set up the system log server path and system log level.
GXV3615WP_HD IP Camera Series IP VIDEO SURVEILLANCE FAQ 1. What is the default IP address of GXV3601/3501/3504? Prior to firmware version 1.0.3.9, the IP address of GXV3501/ 3504/ 3601/ 3611 is 192.168.1.168 at the factory default settings. You can perform a factory reset by pressing the RESET button on the device for 7 seconds. Starting from firmware version 1.0.3.9, the default IP configuration is DHCP. 2.
GXV3615WP_HD IP Camera Series 6. Why does IE indicate to install Grandstream Video Viewer add-on after a firmware upgrade? The add-on was properly installed before the firmware upgrade process. New firmware will often upgrade the add-on as well. To watch the live video stream, you must install the newest version of the add-on. 7. How do you watch secondary video stream? Login to the home page of the GXV3501/ 3504/ 3601/ 3615 web GUI, click Play to watch the video stream.
GXV3615WP_HD IP Camera Series You must set the video resolution to QCIF to watch the GXV3501/3504 /3601 video stream from a cell phone. Make sure to set the bit rate to 64kbps to ensure the best video quality. 14. Why doesn’t the IP address of the device reset when I click the “Restore” button on the Maintenance page? The GXV3501 /3504 /3601 could be installed in areas that are not easy to access. For example, it could be installed on the roof of a building or the ceiling of an office.
GXV3615WP_HD IP Camera Series 7. Tested PC display adapters.
GXV3615WP_HD IP Camera Series FCC Warning This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.