User's Manual
Table Of Contents
P a g e | 33
GXW42xx User Manual
Version 1.0.5.43
Access the Web Configuration Menu
The GXW42XX HTML configuration menu can be accessed via Ethernet port:
To access the HTML configuration menu from the Ethernet port:
1. Follow table 4 to find the Ethernet port IP address.
2. Open a web browser, type in the IP address – for example: http://GXW42XX -IP-Address (the
GXW42XX IP-Address is the Ethernet IP address for the GXW42XX).
Note:
The IVR announces 12 digits IP address, you need to strip out the leading “0” in the IP address. For ex. IP
address: 192.168.001.014, you need to type in http://192.168.1.14 in the web browser.
Once the HTTP request is entered and sent from a web browser, the user will see a log-in screen. There
are two default passwords for the login page:
User Level
Username
Password
Web pages allowed
End User Level
user
123
Only Status and Basic Settings
Administrator Level
admin
admin
Browse all pages
Viewer Level
viewer
viewer
View all pages. Not allowed to
modify the content.
The password is case sensitive with maximum length of 25 characters. Only an administrator can access
the “ADVANCED SETTINGS”, “Profile 1~4”, and “FXS Ports” configuration pages. Please reference the
GUI pages using the following link:
http://www.grandstream.com/sites/default/files/Resources/gxw42xx_gui.zip
Important Settings
The end-user must configure the following settings according to the local environment.
Note: Most settings on the web configuration pages are set to the default values.
NAT Settings
If you plan to keep the gateway within a private network behind a firewall, we recommend using STUN
Server. The following three (3) settings are useful in the STUN Server scenario:
1. STUN Server (under Advanced Settings webpage)