User Manual HandyTone-286 Analog Telephone Adaptor Version 1.00 Grandstream Networks, Inc. www.grandstream.
HandyTone 286 User Manual Grandstream Networks, Inc. Table of Contents 1 WELCOME................................................................................................................................. - 3 - 2 INSTALLATION ........................................................................................................................ - 4 - 3 WHAT IS INCLUDED IN THE PACKAGE ........................................................................... - 5 3.1 4 PRODUCT OVERVIEW ........
HandyTone 286 User Manual 1 Grandstream Networks, Inc. Welcome Congratulations on becoming an owner of HandyTone 286! You made an excellent choice and we hope you will enjoy all its capabilities. Grandstream's award-wining HandyTone 286 is innovative Analog Telephone Adaptor that offers a rich set of functionality and superb sound quality at ultra-affordable price. They are fully compatible with SIP industry standard and can interoperate with many other SIP compliant devices and software on the market.
HandyTone 286 User Manual 2 Grandstream Networks, Inc. Installation HandyTone 286 is a VoIP Analog Telephone Adaptor designed to work with an ordinary analog telephone. The following photo illustrates the appearance of a HandyTone 286.
HandyTone 286 User Manual 3 Grandstream Networks, Inc. What is Included in the Package The HandyTone 286 package contains: 1) One HandyTone 286 2) One universal power adaptor 3) One Ethernet cable 3.1 Safety Compliances The HandyTone 286 is compliant with various safety standards including FCC/CE and C-Tick. Its power adaptor is compliant with UL standard. The HandyTone ATA should only operate with the universal power adaptor provided in the package.
HandyTone 286 User Manual 4 4.1 Grandstream Networks, Inc. Product Overview Key Features • Support SIP 2.0, TCP/UDP/IP, RTP/RTCP, HTTP, ICMP, ARP, DNS, DHCP, NTP/SNTP, TFTP protocols • Support IETF STUN. • Interoperable with various 3rd party SIP end user device, Proxy / Registrar Server and gateway products.
HandyTone 286 User Manual 4.2 Grandstream Networks, Inc. Hardware Specification The table below describes the difference among these models.
HandyTone 286 User Manual 5 5.1 Grandstream Networks, Inc. Basic Operations Get Familiar with Key Pad and Voice Prompt HandyTone 286 has stored a voice prompt menu for quick browsing and simple configuration. To enter this voice prompt menu, simple pick up the phone and press the button on the HandyTone 286; or pick up the phone and dial “***”. The following table shows how to use the voice prompt menu to configure the device.
HandyTone 286 User Manual Grandstream Networks, Inc. Dial ‘86’ to check the voice message “No Voice Messages”; or “Voice Messages Pending” Dial ‘99’ to reset the device “RESET” Dial the invalid number or keypad “Invalid Entry” see “4.2.2 Make a Direct IP Call”.) If there are voice messages, user can dial ‘9’ and dial pre-configured phone number to retrieve voice message.
HandyTone 286 User Manual 5.2 Grandstream Networks, Inc. Make Phone Calls 5.2.1 Calling phone or extension numbers There are currently two methods to make an extension number call: 1) Dial the extension number directly and wait for 5 seconds. 2) Dial the numbers directly, and press # (Assuming that “use #” as dial key is selected in web configuration. For detail, see section 5.2 configure Handytone using web browser).
HandyTone 286 User Manual F 00 01 02 03 04 05 06 07 08 09 *0 *1 *2 *3 *4 21 22 23 31 32 33 41 42 43 51 52 53 61 62 63 71 72 73 74 81 82 83 91 Grandstream Networks, Inc. 0 1 2 3 4 5 6 7 8 9 .
HandyTone 286 User Manual 92 93 94 Grandstream Networks, Inc. X Y Z The rule of thumb to remember these encoding is: “a” is the first letter on button “1” so its encoding is “11”. “b” is the 2nd letter on button “1” and its encoding is “12”. “c” is the 3rd letter on button “1” and its encoding is “13”. Likewise, “d” is the first letter on button “2” and its encoding is “21”. This pattern and rule applies to all other alphabetic encoding. Examples: If the target IP address is 192.168.0.
HandyTone 286 User Manual Grandstream Networks, Inc. To use this feature, dial “*90” and get the dial tone. Then dial the forward number and hang up. *91 Cancel Busy Call Forward To cancel “Unconditional Call Forward”, dial “*91” and get the dial tone, then hang up *92 Delayed Call Forward To use this feature, dial “*92” and get the dial tone. Then dial the forward number and hang up.
HandyTone 286 User Manual 6 6.1 Grandstream Networks, Inc. Configuration Guide Configuring HandyTone IP through Voice Prompt 6.1.1 DHCP Mode Follow section 4.1 with voice menu option 01 to enable HandyTone to use DHCP. 6.1.2 STATIC IP Mode Follow section 4.1 with voice menu option 01 to enable HandyTone 286 to use STATIC IP mode, then use option 02, 03, 04 to set up HandyTone’s IP, Subnet Mask, Gateway respectively. 6.1.3 TFTP Server Address Follow section 4.
HandyTone 286 User Manual Grandstream Networks, Inc. Welcome to Grandstream IP Phone Password Login The password is case sensitive and the factory default password is lower case ‘admin’. 6.2.2 Configuration Menu After the correct password is entered in the login screen, the embedded Web server inside the IP phone will respond with the Configuration Menu screen, which is explained in details below.
HandyTone 286 User Manual Grandstream Networks, Inc. Outbound Proxy This field contains the URI string or the IP address (and port, if different from 5060) of the outbound proxy. If there is no outbound proxy, this field SHOULD be left blank. If not blank, all outgoing requests will be sent to this outbound proxy. SIP User ID This field contains the user part of the SIP address for this phone. e.g., if the SIP address is: sip:my_user_id@my_provider.com, then the SIP User ID is: my_user_id.
HandyTone 286 User Manual Grandstream Networks, Inc.
HandyTone 286 User Manual Grandstream Networks, Inc. Preferred Vocoder The BudgeTone IP phone supports up to 7 different vocoder types including G711-ulaw (PCMU), G711-alaw (PCMA), G723, G729A/B, G726-32 (ADPCM), G728, and iLBC. Depending on the product model, some of these vocoders may not be provided in standard release. A user can configure vocoders in a preference list that will be included with the same preference order in SDP message.
HandyTone 286 User Manual Grandstream Networks, Inc. Voice Frames per TX This field contains the number of voice frames to be transmitted in a single packet. When setting this value, the user should be aware of the requested packet time (used in SDP message) as a result of configuring this parameter. This parameter is associated with the first vocoder in the above vocoder Preference List or the actual used payload type negotiated between the 2 conversation parties at run time. e.g.
HandyTone 286 User Manual Grandstream Networks, Inc. Registration Expiration This parameter allows the user to specify the time frequency (in minutes) the phone will refresh its registration with the specified registrar. The default interval is 60 minutes (or 1 hour). The maximum interval is 65535 minutes (about 45 days). Early Dial This parameter controls whether the phone will attempt to send an early INVITE each time a key is pressed when a user dials a number.
HandyTone 286 User Manual Grandstream Networks, Inc. NAT Traversal This parameter defines whether the phone NAT traversal mechanism will be activated or not. If activated (by choosing “Yes”) and a STUN server is also specified, then the phone will behave according to the STUN client specification. Under this mode, the embedded STUN client inside the phone will attempt to detect if and what type of firewall/NAT it is behind through communication with the specified STUN server.
HandyTone 286 User Manual Grandstream Networks, Inc. Disable Call Waiting Default is Not. Send DTMF This parameter controls the way DTMF events are transmitted. There are 3 ways: in audio which means DTMF is combined in audio signal (not very reliable with low-bit-rate codec), via RTP (RFC2833), or via SIP INFO.
HandyTone 286 User Manual Grandstream Networks, Inc. Grandstream IP Phone Configuration Update Status Your configuration changes have been saved. They will take effect on next reboot. Back to Home Page 6.2.4 Rebooting the phone from remotely The administrator of the phone can remotely reboot the phone by pressing the “Reboot” button at the bottom of the configuration menu. Once done, the following screen will be displayed to indicate that rebooting is underway.
HandyTone 286 User Manual Grandstream Networks, Inc. other communication protocols to communicate with each individual IP phone even if the phone is behind a NAT. GAPS must be used to support automated configuration of an IP phone. To enable this feature on the phone, the user just needs to enter the IP address of GAPS server in the tftp server field of the configuration screen. Then power cycle the phone. For details on how GAPS works, please refer to the documentation of GAPS product.
HandyTone 286 User Manual 7 Grandstream Networks, Inc. Software Upgrade with TFTP To upgrade software, HandyTone ATAs can be configured with a TFTP server where the new code image is located. The TFTP upgrade can work in either static IP or DHCP mode using private or public IP address. It is recommended that the TFTP server must have either public IP address or be on the same LAN with the HandyTone ATA.
HandyTone 286 User Manual 8 Grandstream Networks, Inc. Restore Factory Default Setting Warning: Restore the Factory Default Setting will delete all configuration information of the device. Step one: Find the Mac Address of the device. The Mac address of the device is located on the bottom of the device. It is a 12 digit number. Step two: Encode the Mac address. The encode rule is: “2” is the first letter on the button “2” so its encoding is “2”.