User's Manual
FIRMWARE VERSION 1.0.7.6 HT502 USER MANUAL Page 33 of 48
SIP TLS Private Key
Password
User specify password to protect the private key above.
ACS URL
User specify the Auto Configuration Server’s URL (TR-069 protocol)
ACS Username
User specify the ACS Username
ACS Password
User specify the ACS password
Periodic Inform
Enable
Default is No. If set to YES, device will send inform packets to the ACS
Periodic Inform
Interval
Frequency that the inform packets will be sent out to the ACS
Connection Request
Username
Set a user name for the ACS to connect to this device
Connection Request
Password
Set a password for the ACS to connect to this device
Connection Request
Port
Set a port number for the ACS to connect to this device, default is 7547
CPE SSL Certificate
Configure the SSL authentication of Customer-premises equipment
CPE SSL Private Key
Configure the SSL Private Key of Customer-premises equipment
System Ring Cadence
Configuration option is set ring cadence on all FXS ports for all incoming calls. (Syntax:
c=on1/off1-on2/off2-on3/off3(only 3 cadences maximum)) Default is set to c=2000/4000;
(US standards)
Call Progress Tones
Using these settings, users can configure tone frequencies and cadence according to
their preference. By default they are set to North American frequencies. Configure these
settings with known values to avoid uncomfortable high pitch sounds. ON is the period of
ringing (“On time” in ‘ms’) while OFF is the period of silence. In order to set a continuous
tone, OFF should be zero. Otherwise it will ring ON ms and a pause of OFF ms and then
repeat the pattern.
Example configuration for N.A. Dialtone:
f1=350@-13,f2=440@-13,c=0/0;
Syntax: f1=freq@vol, f2=freq@vol, c=on1/off1-on2/off2-on3/off3; [...]
(Note: freq: 0 - 4000Hz; vol: -30 - 0dBm)