User's Manual
Table Of Contents
- CHANGE LOG
- WELCOME
- GATEWAY GXW450X OVERVIEW
- GETTING STARTED
- SYSTEM STATUS
- SYSTEM SETTINGS
- TRUNKS
- PBX SETTINGS
- MAINTENANCE
- CDR (Call DETAIL RECORD)
- EXPERIENCING THE GXW450X SERIES DIGITAL GATEWAY
Page | 72
GXW450X User Manual
Version 1.0.0.6
Framing
If span type is E1, the signaling configure as MFC/R2, then framing must
configure as "cas"; If span type is E1, the signaling configure as PRI or
SS7, then framing must configure as "ccs"; If span type is T1, and the
signaling configure as PRI or SS7, then framing can configure as "esf" or
"d4"; If span type is J1, and the signaling configure as PRI or SS7, then
framing can configure as "esf" or "d4".
CRC Validation
For E1, select whether to use CRC4 or None.
Advanced Settings
Called Nature of Address
Indicator
Indicates the type of the called number. The receiving switch may use this
indicator during translations to apply the number’s proper dial plan. Users
can select "Unknown", "Subscriber", "National", "International" or
"Dynamic".
Calling Nature of Address
Indicator
Indicates the type of the calling number. The receiving switch may use this
indicator during translations to apply the number’s proper dial plan. Users
can select "Unknown", "Subscriber", "National", "International" or
"Dynamic".
International Prefix
National Prefix
Subscriber Prefix
Unknown Prefix
Configure the prefix in Called Nature of Address Indicator and Calling
Nature of Address Indicator for each type.
Table 24: Digital Hardware Configuration Parameters: E1 - MFC/R2
Basic Settings
Clock
All E1/T1/J1 spans generate a clock signal on their transmit side. The
parameter determines whether the clock signal from the far end of the
E1/T1/J1 is used as the master source of clock timing. If the far end is
used as the master, the gateway system clock will synchronize to it.
• Master:
The port will never be used as a source of timing. This is
appropriate when you know far end should always be a slave to you.
• Slave: The equipment at the far end of the E1/T1 link is the preferred
source of the master clock.