User's Manual
Table Of Contents
- CHANGE LOG
- WELCOME
- GATEWAY GXW450X OVERVIEW
- GETTING STARTED
- SYSTEM STATUS
- SYSTEM SETTINGS
- TRUNKS
- PBX SETTINGS
- MAINTENANCE
- CDR (Call DETAIL RECORD)
- EXPERIENCING THE GXW450X SERIES DIGITAL GATEWAY
Page | 80
GXW450X User Manual
Version 1.0.0.6
Port
Configure the digital channel group used by the trunk.
Hide CallerID
Configure to hide outgoing caller ID. The default setting is "No".
Caller ID
Configure the Caller ID. This is the number that the trunk will try to use
when making outbound calls. For some providers, it might not be possible
to set the CallerID with this option and this option will be ignored.
CallerID Name
Configure the name of the caller.
DAHDI Out Line Selection
This is to implement Digital trunk outbound line selection strategy. Three
options are available:
• Ascend: When the call goes out from this digital trunk, it will always
try to use the first idle digital port. The port order that the call will use
to go out would be port 1port 2port 3port 4. Every time it will
start with port 1 (if it’s idle).
• Poll: When the call goes out from this digital trunk, it will use the port
that is not used last time. And it will always use the port in the order of
port 12341234123
4…, following the last port
being used.
• Descend: When the call goes out from this digital trunk, it will always
try to use the last idle digital port. The port order that the call will use
to go out would be port 16port 10port 2port 1. Every time it will
start with port 4 (if it’s idle).
The default setting is “Ascend” mode.
Digital Trunk Troubleshooting
After configuring the digital trunk on the GXW450X as described above, if it doesn't work as expected,
users can go to capture signaling trace on the GXW450X Web GUI for troubleshooting purpose.
Depending on the signaling selected for the digital trunk, users can go to following pages to capture trace:
PRI Signaling Trace: Web GUIMaintenanceSignaling TroubleshootingPRI Signaling Trace
SS7 Signaling Trace: Web GUIMaintenanceSignaling TroubleshootingSS7 Signaling Trace
MFC/R2 Signaling Trace: Web GUIMaintenanceSignaling TroubleshootingMFC/R2 Signaling
Trace