Install Manual

13
PROJECTOR LIFT POSITIONING FUNCTION
There are 2 solutions to position the projector lift: upper/lower limitation and
remote localizer. NOTE: Changing these limits will void warranty.
NOTE: Do not change the factory pre-settings for any emergency, please operate
according to the following instructions if necessary.
1. Remote limit setting adjustment (Soft Limits)
a. When the projector lift installation has been completed, turn on the power to the lifter.
Confirm the lifter is operational.
b. To set the lower limit (show position), turn over the remote control and locate the limit
setting button. Press this button using a small pin or paperclip for 3 seconds and
release (red LED will light up). Then press the down button on the front of the remote.
Then the lifter is at the correct show position press stop. Turn over the remote again
and press the limit setting button, the red LED will go out and the new limit is set.
figure 16 figure 17
c. To set the upper limit (closed position), turn over the remote control and locate the
limit setting button. Press this button using a small pin or paperclip for 3 seconds and
release (red LED will light up). Then press the up button on the front of the remote.
Then the lifter is at the correct closed position press stop. Turn over the remote again
and press the limit setting button, the red LED will go out and the new limit is set.
figure 18 figure 18
NOTE: For ensuring the security of positioning function, the eective setting period
of electric positioning should be 60 seconds, after which it will return to the normal
situation. If the setting fails within 60 seconds, please repeat the following steps:
to press the setting button – LED light will turn o; press the setting button again
– LED light will turn on. With this process the resetting function will begin.
2. Upper/Lower Limitation Adjustment (Hard Limits)
Upper limitation and lower limitation are preset in the factory. The upper limitation
should be a little higher than ceiling height. Lower limitation is showed as numerical value
D in the specification table (the upper/lower limitation for sling wire should be regulated
by professional people or dealers. Improper regulation carries safety risks).
(See figures 12 & 13 on page 14)