EZ Pitched Roof System SunModo PV Rack Mounting System UL2703 Compliant Pub.
EZ Pitched Roof System Please read carefully before installing Product is tested to and recognized to UL 2703 standards for safety grounding and bonding equipment and meets UL 1703 fire standards. SunModo PV Rack Mount System can be used to mount photovoltaic (PV) panels in a wide variety of locations. All installations shall be in accordance with NEC requirements in the USA. The self-bonding system is for use with PV modules that have a maximum series fuse rating of 30A.
EZ Pitched Roof System Landscape Panel Configuration: .................................................................................................... 27 Minimum Panel Height ...................................................................................................... 28 End Clamp Attachment ....................................................................................................... 28 Mid Clamp Attachment ..............................................................................
EZ Pitched Roof System Installer Responsibility: Before ordering and installing materials, all system layout dimensions should be confirmed by field measurements. SunModo reserves the right to alter, without notice, any details, proposals or plans. Any inquiries that you may have concerning installation of the PV system should be directed to your SunModo Sales representative. Consult SunModo Sales for any information not contained in this manual.
EZ Pitched Roof System Lag Pull-Out Capacities: Sources: American Wood Council, NDS 2005, Table 11.2 A, 11.3.2 A Notes: Lag pull-out (withdrawal) capacities (lbs.) in typical lumber: Douglas Fir, Larch Douglas Fir, South Engelmann Spruce, Lodgepole Pine (MSR 1650 f & higher) Hem, Fir Hem, Fir (North) Southern Pine Spruce, Pine, Fir Spruce, Pine, Fir (E of 2 million psi and higher grades of MSR and MEL) Specific Gravity .50 .46 .46 .43 .46 .55 .42 .
EZ Pitched Roof System SunModo Self-Bonding System SunModo developed a proprietary grounding and bonding system that is built into the mounting hardware for the rails, clamps and splices. We provide further grounding through all of the SunBeam racking components including the Pipe Caps, Beams, Posts and Post Base Plates. All hardware meet UL 2703 Grounding and Fire Standards tested by ETL.
EZ Pitched Roof System EZ Roof Mount System Components Primary Materials EZ Roof Mount Kit includes: Flashing L-Foot Roof Shoe and Gasket 4” Lag Bolt AL Hex Cap 3/8” Flange Nut and Bolt K10068-XXX EZ Roof Mount with L-Foot (-001 as shown) EZ Roof Mount Standoff Kit: Flashing L-Foot Roof Shoe and Gasket 4” Lag Bolt AL Hex Cap 3/8” Flange Nut and Bolt Standoff: 2” shown EZ Metal Roof Mount Kit includes: L-Foot Metal Roof Shoe and Gasket 4” Lag Bolt AL Hex Cap 3/8” Fl
EZ Pitched Roof System Aluminum Flashings are offered in two sizes: 10”X12.5” and 18”X18”. Available in clear, black and brown anodize. A20052-XXX AL Flashing Aluminum L-Foot is offered in clear, black and brown. A20064-XXX AL L-Foot AL Hex Cap Available in clear and black A20066-001 and -BK1 AL Hex Cap Aluminum Shoe is provided with EPDM Sealing Washer installed. Aluminum Shoe (for metal roofs) is provided with EPDM Sealing Washer installed.
EZ Pitched Roof System K10066-XXX Standard L-Foot Kit Aluminum L-Foot available in clear and black. K10096-XXX Tall L-Foot Kit (3/8” Flange Nut and Bolt included) Aluminum Standoff heights: 2”, 3”, 5” and 7” (part of EZ Roof Kit K10070-XXX) Helio Rails: Features both 1/4” and 3/8” side slots, and 1/4” top slot for clamping PV panels. Available in 84”, 124”, 164” and 206” lengths. Last 3 digits denote rail length. 4 stock sizes in clear and black.
EZ Pitched Roof System 1/4” Slot Rail Splice Kit with 4X bolts and flange nuts with integral grounding. May be repositioned until torqued to final value. K10177-001 K10177-BK1 HR250/HR350 1/4” Splice For single-use only End Clamp Kit, fits panel height from 31 to 50 mm. For last 3 digits, see table on last page. K10224-1XX K10224-1XX-BK Adjustable End Clamp Kit, fits panel height from 33 to 50 mm. K10299-001 K10299-BK1 Adjustable End Clamp Kit, fits panel height from 30 to 46 mm.
EZ Pitched Roof System Grounding Lug Kit with Grounding Spacer and 1/4-20 T-Bolt. May be repositioned until torqued to final value. K10179-001 For single-use only HR150 (Open Rail): Features wire management channel and both 1/4” and 3/8” side slots, and 1/4” top slot for clamping PV panels. Available in 124” and 166” lengths. Last 3 digits denote rail length. 4 stock sizes in clear anodized and black.
EZ Pitched Roof System List of Compliant PV Modules UL 2703 Qualified Modules for use with SunModo PV Racking Systems Evaluated PV Modules Module manufacturer Model numbers Boviet Solar BVM6610M-250, BVM6610M-255, BVM6610M-260, BVM6610M-265, BVM6610M270, BVM6610M-275, BVM6610M-280, BVM6612M-325, BVM6612M-330, BVM6612M-335, BVM6612M-340, BVM6612M-345, BVM6612M-350, BVM6610P250, BVM6610P-255, BVM6610P-260, BVM6610P-265, BVM6610P-270, BVM6612P310, BVM6612P-315, BVM6612P-320, BVM6612P-325, BVM6612P-330 C-Su
EZ Pitched Roof System Kyocera KD315GX-LFB, KU260-6MCA, KU265-6MCA, KD255GX-LFB2, KD260GX-LFB2, LG LG275S1C-G4, LG280S1C-G4, LG285S1C-G4, LG300N1C-G4, LG300N1K-G4, LG300N1T-G4, LG305N1C-G4, LG305N1K-G4, LG310N1C-G4, LG310N1K-G4, LG310N1T-G4, LG315N1C-G4, LG320N1C-G4, LG335S2W-G4, LG340S2W-G4, LG360N2W-B3, LG365N2W-B3, LG365N2W-G4, LG370N2W-G4, LG375N2W-G4, LG380N2W-G4, LG385N2W-G4, LG390N2W-A5, LG395N2W-A5, LG400N2W-A5 Mitsubishi PV-MLE270HD, PV-MLE275HD, PV-MLE280HD Panasonic VBHN285J40 Phono Solar
EZ Pitched Roof System SolarWorld (V2.
EZ Pitched Roof System Fault Current Path Diagram Items are listed in the fault current path in order from the PV Panel to the Grounding Lug: 1. 2. 3. 4.
EZ Pitched Roof System Tools Required for Installation Electric Drill or Impact Driver. Note that the use of an impact driver is strongly discouraged for all stainless nut and bolt hardware. Roofing Bar Drill Bit for lag bolts, pilot hole 7/32” diameter for 5/16” lag bolt 3/8” Socket wrench Sockets for 3/8” drive sockets, 7/16”, 1/2”, 9/16” and 1-1/16” Torque Wrench 3/8” drive, 0 to 35 ft. lbs.
EZ Pitched Roof System Anti-seize compound (Permatex 80071 or equivalent). Caulk gun and silicon sealant ChemLink M1 (or equivalent) for wood and composite roofs. ChemLink DuraLink (or equivalent) for metal roofs.
EZ Pitched Roof System Torque Values for Pitched Roof System These values must be adhered to, both for mechanical strength and to insure the performance of the integral grounding and bonding features. It is required that a torque wrench be used to measure the bolt torque during final assembly, and it is recommended that anti-seize compound be applied to the screw threads. Hardware Torque lbs. 1/4-20 Bolts and Hex Flange Nut 7.5 ft. lbs. 1/4-20 Ground Lug, Flange Nut with 7/16 Hex Head 7.5 ft. lbs.
EZ Pitched Roof System Flashing Placement: Best Position No shingle cutting required Acceptable Position If shingle cutting is required a 1/2" gap between the raised feature of the Flashing and the shingle is recommended. If cutting the shingle or repositioning the flashing proves to be impractical, we recommend applying sealant under the overhanging edge of the Flashing to prevent debris from accumulating on the shingle.
EZ Pitched Roof System Installation Instructions: EZ Roof Mount Kit K10068-XXX 1. From the marked location, move down the roof 2-1/4” from the bottom of the shingle, and drill the pilot hole for the Lag Bolt with a 7/32” drill bit. For maximum strength, the hole should not be more than 3” in depth, and a drill stop may be used to insure this. 1 2. Clean sawdust, and fill hole with sealant, such as Chemlink M1 for wood and composite roofs, or ChemLink DuraLink for metal roofs.
EZ Pitched Roof System Installation Instructions: EZ Roof Mounting Standoff Kit K10070-XXX Mount the AL Shoe using steps 1-3 (shown above). A. Place AL Standoff on AL Shoe threads and tighten by hand, then by wrench. Use 15 ft.-lbs. nominal torque. A B. Using the 3/8” Flange Bolt (supplied with AL L-Foot) attach to the top of the Standoff. B C. Install AL Rail to L-Foot to the specific orientation. Then, tighten 3/8” Flange Nut to 15 ft-lbs. and Hex Cap to 15 ft-lbs. torque.
EZ Pitched Roof System Optional Mounting Instructions: 2-1/4” EZ Roof Mount Kit K10068-B20 1. From the desired location, move down the roof 2-1/4” from the bottom of the shingle, and locate the EZ Roof Mount AL Shoe center. The AL Shoe will be used as a template to locate the 4 screws. 2. Place a bead of Chem-link M1 for wood and composite roofs along the length of the screw four (4) 1/4” X 3” selfdrilling Decking Screws. Mount the AL Shoe to the roof through the shingles using the four Decking Screws.
EZ Pitched Roof System Installation Instructions: EZ Metal Roof Mount Kit K20051-XXX 1. From the marked location drill the pilot hole for the Lag Bolt with a 7/32” drill bit. For maximum strength, the hole should not be more than 3” in depth, and a drill stop may be used to insure this. 1 2. To ensure a strong and water tight seal, wipe away excess grease or debris from the mounting location. Fill pilot hole with sealant, such as ChemLink DuraLink for metal roofs.
EZ Pitched Roof System Installation Instructions: EZ Metal Roof Mounting Standoff Kit K10064-XXX Mount the AL Shoe using steps 1 and 2 (shown above). A A. Place AL Standoff on AL Shoe threads and tighten by hand, then by wrench. Use 15 ft.-lbs. nominal torque. B. Using the 3/8” Flange Bolt (supplied with AL LFoot) attach to the top of the Standoff. C. Install AL Rail to L-Foot to the specific orientation. Then, tighten 3/8” Flange Nut to 15 ftlbs. and Hex Cap to 15 ft-lbs. torque.
EZ Pitched Roof System Portrait Panel Configuration: With a full range of components the Pitch Roof System can be configured in an endless variety of designs. The system is IBC compliant for roof waterproofing tested by IAPMO, UL 1703 compliant for Class-A Fire Rated for Type 1 and 2 PV Modules and UL 2703 compliant for electrical bonding tested by ETL. Proceed with the mounting of the PV panels using the Mid and End Clamps.
EZ Pitched Roof System Minimum Panel Height Minimum leading edge height to meet a UL1703 PV module fire standard is 3 inches. 3 inch minimum from bottom of PV module frame to the roof covering End Clamp Attachment There must be a minimum of 1.5 inches of Rail extending beyond the PV panel frame. Clamp the PV panel frame by inserting the T-Bolt into the Rail slot. Position the End Clamp firmly against the PV panel frame and secure using the 1/4-20 Collar Bolt. Using a 7/16” socket, torque to 7.5 ft. lbs.
EZ Pitched Roof System Landscape Panel Configuration: The Pitched Roof System conveniently accommodates landscape configurations to minimize roof time and parts required. The system is IBC compliant for roof waterproofing tested by IAPMO, UL 1703 compliant for Class-A Fire Rated for Type 1 and 2 PV Modules and UL 2703 compliant for electrical bonding tested by ETL. Proceed with the mounting of the PV panels using the Mid and End Clamps.
EZ Pitched Roof System Minimum Panel Height Minimum leading edge height to meet a UL1703 PV module fire standard is 3 inches. 3 inch minimum from bottom of PV module frame to the roof covering End Clamp Attachment End Clamps are used at the ends of a row of PV panels. Insert the T-Bolt in the Rail slot and turn clockwise 90° to engage the head into the slot. Insert Grounding T-Bolt Holder to lock T-Bolt in place. Thread the 1/4” Collar Bolt onto the top of the TBolt as shown.
EZ Pitched Roof System Ground Wire Attachment The picture shows a grounding lug mounted on one Rail per row of panels, and a #6 solid copper grounding wire connecting the Ground Lugs to the building ground per NEC 690.47. Ground Lug Installation One Rail per row of panels should have a Ground Lug for fastening the ground conductor to the array. The Ground Lug is mounted on the top or side of the Rail using a special 1/4” TBolt, Grounding Spacer, and Flange Nut.
EZ Pitched Roof System UL 2703 Label Placement When requested the UL 2703 Label can be located on East-West running Rail or Beam. See www.sunmodo.com for current warranty documents and information.