User's Manual

10 / 36
S1035_Falcon_12_jh_V1
Power supply
The receiver does not feature specific sockets for connecting the
battery. We recommend that you connect the power supply to the
socket(s) close to the servos already connected to the receiver. If you
wish to connect multiple separate batteries, the batteries must be
of the same nominal voltage and capacity. Never connect different
battery types or batteries with strongly different charges since this
can cause an effect similar to a short circuit. In such cases for safety
reasons, insert voltage stabilizing elements such as PRX-5A (No.
4136) receiver power supplies between the batteries and receiver.
Programming the receiver settings
The receiver can be programmed with a suitable HoTT transmitter
or in connection with the SMART-BOX.
Receiver settings menu
The receiver setup menu appears in the “Telemetry“ menu under
SETTINGS / DISPLAYS or if you are using a SMART-BOX under SET-
TING & DATAVIEW. How to access this menu is described in the oper-
ating instructions supplied with your transmitter or Smart-Box.
Model type
Setting "HELI" or "Fixed-wing". The following specific setting menus
will appear depending on the model type selected. Factory reset for
heli settings: Switch from heli to fixed-wing then disconnect the
power supply and reconnect it.
Then switch from fixed-wing to heli, disconnect the power supply
and reconnect it.
Low voltage warning (ALARM VOLT)
If the receiver voltage or the external voltage at channel 5 falls below
the set value, a low-voltage warning is generated by the transmit-
ter's RF module in the form of a "general alarm tone" (regular beep-
ing at a rate of approx. one beep per second) or the "receiver volt-
age" speech output message.
Temperature warning (ALARM TEMP)
If the receiver temperature exceeds the set temperature, a warning
is generated by the transmitters RF module in the form of a "general
alarm tone" (regular beeping at a rate of approx. one beep per sec-
ond) or the "receiver temperature" speech output message.
RECEIVER 2.0 <
>LANGUAGE: English
Model type: HELI
ALARM VOLT 3,8V
ALARM TEMP: 70°C
CYCLE: 20ms
SUMD at C5: No
C5: Sensor