User's Manual

11 / 36
S1035_Falcon_12_jh_V1
Cycle time (CYCLE)
If your system is used exclusively with digital servos, you can set a
cycle time (frame rate) of 10 ms. If your system includes some or
uses exclusively analogue servos, you should always select 20 ms, as
many analogue servos cannot process the higher frame rate and
may respond by "jittering" or "growling".
SUMD (Sum signal) at channel 5
If you activate the digital sum signal at channel 5, a sum signal con-
taining 8 channels is present at this socket, instead of a servo signal.
The HoTT receiver configured as SUMD constantly generates a digi-
tal sum signal from 8 control signals from the transmitter and makes
this signal available at the specified servo socket, which is receiv-
er-specific. This type of signal was being used by some of the newest
flybarless systems and power supplies.
Channel 5 (C5)
This socket allows you to use either for telemetry "Sensor" or for an
extra channel servo 5 "Servo" or or for measuring the voltage "Volt-
age".
Attention! It is only possible one function at the same time!
Only through the unit described in the introduction it is possible to
measure a voltage up to max. 25.5 V DC. This voltage will be shown
in the display of the transmitter instead the receiver voltage. This
way it is possible to monitor the main battery voltage without using
external sensors.
Note
If the voltage measurement is active, the following described switch
(see sketch) must be used to measure a maximal voltage of 25.5 V
through this output. Never connect a battery to this telemetry port
without this switch!
This voltage distributor is included in the ESCs S3082 and S3083.
<- Channel 9