User's Manual

27 / 36
S1035_Falcon_12_jh_V1
Swp rate
50 -120, default setting 85
Sets the max. potential rate of rotation in Rate mode for roll and nick.
Expo Swp
0 -50, default setting 15
You can set here an exponential curve (0 - 50%) for the rate of roll
and nick. Low percentages result in a linear increase in the rate of
rotation. High percentages a strong curve, the heli then no longer
reacts so sensitive to the center of the stick. We recommend to use
the Expo in the GR18 or in the transmitter. When using the expo in
the transmitter, the value here must be set to 0, otherwise the two
Expo settings overlap.
Direct stick R (Roll), Direct stick N (Nick)
20 -150, default setting +115
The direct stick setting allows you to set the direct response of the
helicopter to the pilot's commands. If the nick command stops
abruptly, the helicopter will oscillate if the value is set too high.
Swashplate setting with Expertmode
(See above for swashplate sensitivity menu item)
(See above for Rate and Expo menu item)
(See above for direct stick menu item)
P swp (proportional) swashplate
Swashplate P-factor
40 - 125, default setting: +90
The P swashplate option is responsible for effecting a harder stop
with the swashplate. Higher values result in a faster stop. If the P val-
ues are too high, the helicopter and/or the swashplate will start to
"oscillate". In such cases, the value must be reduced again.
I swp (integral) swashplate
Swashplate I-factor
30 - 125, default setting: +85
Servo travel
Servo travel
Servo travel
Control travel
Control travel
Control travel
Expo = +100%
Expo = +50%
Expo = –100%
SWASHPLATE ADJUST<v>
>SWP sensitivity(5)K9
Swp rate +85
EXPO Swp +15
Direct stick R +125
Direct stick N +125
P swp +100
I Swp +70
D Swp +25
Speedflight +20
Stop optimizer +6
Anti-ballooning +0