User manual

119Program description - Control adjust | Winged models
0%
0%
0%
–––
0%
–––
–––
–––
GL
GL
GL
GL
nor mal
fr
fr
fr
fr
SEL
In5
offset
In6
In7
In8
typ
„GL“
The settings for the input in question affect all
flight phases programmed (if any) and thus act
“globally” on the model memory in question.
“PH”
The settings for this input take effect per flight
phase and must therefore be configured separate-
ly for each flight phase.
Notes:
See page 150 for more information about flight
phases.
The current positions of the INC/DEC buttons CTL
5 & 6, which are generally assigned to inputs 5 …
8 or 5 … 12, are stored in accordance with your
chosen entry in the “Type” line, i. e. the settings are
not lost when you switch flight phases or change
models.
The particular advantage of these two transmitter
controls especially if you select the “PH” setting -
lies in the fact that you can use one and the same
INC/DEC button as trim controls in all the pro-
grammed flight phases, but in contrast to a posi-
tion-related proportional control the trim values
are retained even if you switch models.
Column 3,
“Transmitter control and switch assignment”
Select an input, 5 through 12 max., with the  se-
lection keys of the left or right four-way button.
Transmitter control assignment
Use the selection keys to move into the column la-
beled SEL. After completing the activation of trans-
mitter control assignment by tapping the center SET
key of the right four-way button, the message shown
below will appear in the display:
0%
0%
0%
–––
0%
GL
normal
fr
SEL
In5
offset
In6
In7
In8
typ
Move desired
control adj.
Now actuate the desired transmitter control: The no-
tice window will disappear and the designation of the
selected transmitter control will appear in the trans-
mitter control assignment window.
0%
0%
0%
–––
0%
–––
–––
–––
GL
GL
GL
GL
nor mal
fr
Lv2
fr
fr
SEL
In5
offset
In6
In7
In8
typ
Switch assignment
If the input is to be actuated like a switch module, the
input can alternatively be assigned to a switch.
A simple switch can be used to switch back and forth
between two limit values, for example motor On/Off.
A 3-way momentary or toggle switch achieves the
same effect as a 2-channel switch module, for exam-
ple motor Off/Half/Full.
Use the selection keys to move into the column above
the
switch symbol label. Briefly tap the center
SET key of the right four-way button to activate the
option for assigning a switch:
0%
–––GL
normal
fr
SEL
In5
offset
typ
Move desired switch
to ON position
(ext. switch: SET)
Actuate the desired toggle switch from its “OFF” to its
“ON” position or, for a 3-way switch, beginning from
its middle position, assign a switch direction prefer-
ably the “second” direction. This means, if a function
is to be switched on by moving the switch forward two
positions, i. e. away from the pilot, then begin from the
switch’s middle position and move the switch away
from the pilot.
The display will then present the switch number to-
gether with a symbol indicating the given switch direc-
tion. At the same time, the column label in the footer
line will change from SEL into another switch symbol:
0%
0%
0%
–––
0%
–––
–––
–––
GL
GL
GL
GL
normal
fr
fr
fr
3
In5
offset
In6
In7
In8
typ
Now put the 3-way switch back into its middle posi-
tion. Move the marker frame as necessary to the left
into the column labeled with the new switch symbol,
briefly tap on the center SET key of the right four-way
button then assign the switch’s other switch direction
by once again starting from the middle position but
this time move the switch in the other direction.
The display will now present the given switch number
together with a symbol indicating the given switch
direction, for example: