User manual

153Program description - Phase settings | Winged models
This counter field is highlighted as soon as the
switch for the “Time1” timer is “opened”, i. e. the
timer is stopped:
GRAUBELE
#01
2:22h
Stp
Flt
«Speed »
0:00
0:00
5.5V
3.9V
0:00.0
M
Time1
00
When necessary, the selection keys can be used
to access and read the sequence of switching
times.
Application:
Measurement of e. g. motor switch-on times, if the
same switch also actuates the motor.
Time2
This timer stores both the “off” and the “on” peri-
ods for the associated switch, i. e. every switch ac-
tuation in either direction will cause a record to be
written for the timer, the timer will be reset then
starts incrementing by “1” again as time passes.
Each time count can be suspended with the cent-
er ESC key of the right four-way button, without
actuating the switch itself. Activating the switch, in
turn, increments the counter by 1 and restarts the
“Time2” timer.
In order to read out the time memory with the se-
lection keys, the “Time2” timer must first be sus-
pended by using the ESC key of the right four-way
button.
Application:
In addition to the motor runtimes, for example, the
unpowered glide times between these could also
be recorded.
A simultaneous tap on the  or  keys of the
right four-way button (CLEAR) will reset suspended
timers shown in the basic display.
Column “Motor”
Note:
This column is only available if “forward/back” is
present in the “Motor on C1” line of the »Model type«
menu.
Pha1
Pha2
Pha3
Name motor
Pha4
Pha5
+
+
Normal
Launch
Dist.
yes
yes
yes
yes
yes
“yes”
The motor connected to receiver output 1 will be
controlled by the C1 stick (throttle/brake stick).
The brake system to be set up on the »Wing mix-
ers« menu is deactivated:
Brake settings
normal
OFF
“no”
The motor connected to receiver output 1 is de-
coupled from the C1 stick (throttle/brake stick) and
is held in its OFF position as specified by the set-
ting “Throttle min. forward / back” automatically.
The brake system to be set up in the »Wing mix-
ers« menu is activated and is actuated by the C1
stick:
Elevat curve
Brake settings
AILE
Crow
D.red
0%
0%
normal
Note:
The settings available depend on the number of
control surface servos selected on the line “Ailer-
ons/Camber-changing flaps in the »Model type«
menu.
Column “Sw. time”
When you switch between flight phases, it is advis-
able to use this column to program a switch time for a
“soft” transition INTO (!) the respective phase. Accord-
ingly, there is also an option for specifying a different
time for the switchover from any phase to, for exam-
ple, Phase 3 than for a switchover to Phase 1.
Use the selection key of the left or right four-way
button to move the marker frame to the right beyond
the column labeled “Timer” and, if applicable, also the
column labeled “Motor”.
Pha1
Pha2
Pha3
Name Sw.time
Pha4
Pha5
+
+
Nor mal
Launch
Dist.
0.1s
0.1s
0.1s
0.1s
0.1s
Following a brief tap on the center SET key of the
right four-way button, the switchover time value in the
field displayed in inverse video can be changed within
a range of 0 and 9.9 s: