Program description - Telemetry
RX CURVE
TYPE : A
CURVE1 CH : 02
TYPE : A
CURVE2 CH : 03
TYPE : B
CURVE3 CH : 04
5CH FUNCTION:SENSOR
Another tap on the center SET key of the right four-
way button will close the selection and, with appropri-
ate repetitive taps on the center ESC key of the left
four-way button, a return to the transmitter’s basic
display is accomplished.
RX SERVO TEST
RX SERVO TEST
ALL–MIN : 1000µsec
ALL–MAX : 2000µsec
ALARM VOLT : 3.8V
TEST : STOP
ALARM TEMP–:–10°C
ALARM TEMP+: 55°C
CH OUT TYPE:ONCE
Value Explanation
Possible
settings
ALL-MAX Servo travel on the
"+" side for all servo
outputs for the
servo test
1500 … 2000 µs
ALL-MIN Servo travel on the
"-" side for all servo
outputs for the
servo test
1500 … 1000 µs
TEST Test procedure START / STOP
ALARM
VOLT
Alarm threshold
of the receiver
undervoltage
warning
3.0 … 7.5 V
factory setting:
3.8 V
ALARM
TEMP+
Alarm threshold for
excessively high
temperature of the
receiver
50 … 80 °C
Factory setting:
55 °C
ALARM
TEMP–
Alarm threshold
for excessively low
temperature of the
receiver
-20 … +10 °C
Factory setting:
-10 °C
CH
OUTPUT
TYPE
Channel sequence ONCE, SAME,
SUMI, SUMO and
SUMD
ALL-MAX (servo travel on the “+” side)
In this line you set the maximum servo travel on the
plus side of the control travel for the servo test.
2000 µs corresponds to the full throw; 1500 µs corre-
sponds to the neutral position.
Make sure that the servos do not overrun mechani-
cally during the test routine.
ALL-MIN (servo travel on the “-” side)
You adjust the maximum servo travel on the minus
side of the control path for the servo test in this line.
1000 µs corresponds to the full throw; 1500 µs corre-
sponds to the neutral position.
TEST
You start and stop the servo test integrated in the
receivers in this line.
A brief tap on the center SET key of the right four-way
button will open the entry field:
RX SERVO TEST
ALL–MIN : 1000µsec
ALL–MAX : 2000µsec
ALARM VOLT : 3.8V
ALARM TEMP–:–10°C
ALARM TEMP+: 55°C
CH OUT TYPE:ONCE
TEST : STOP
Now, with one of the selection keys of the right four-
way button, select START:
RX SERVO TEST
ALL–MIN : 1000µsec
ALL–MAX : 2000µsec
ALARM VOLT : 3.8V
ALARM TEMP–:–10°C
ALARM TEMP+: 55°C
CH OUT TYPE:ONCE
TEST : START
A brief tap on the center SET key of the right four-way
button will now start the test run. The input field is
shown as “normal” again:
RX SERVO TEST
ALL–MIN : 1000µsec
ALL–MAX : 2000µsec
ALARM VOLT : 3.8V
ALARM TEMP–:–10°C
ALARM TEMP+: 55°C
CH OUT TYPE:ONCE
TEST : START
To stop the servo test, reactivate the entry field as
described above, select STOP and confirm this selec-
tion with the SET key of the right four-way button.
ALARM VOLT (receiver undervoltage warning)
The receiver voltage is monitored through ALARM
VOLT. The interval can be adjusted between 3.0 and
7.5 Volt. If the set alarm threshold is undercut, an
acoustic signal is issued (interval peep tone long/
short) and “VOLT.E blinks in the top right of all »RX
« displays:
RX SERVO
REVERSE : OFF
CENTER : 1500µsec
TRIM : –000µsec
TRAVEL– : 150%
OUTPUT CH: 01
TRAVEL+ : 150%
PERIOD : 20msec
VOLT.E
The parameter “R-VOLT is also represented inverse-
ly in the »RX DATAVIEW« display: