User manual

289Programming examples - Winged models
Note:
No delay is entered on the “OFF” side, so that the
drive can be switched off instantly at any time. This
does not additionally stress the drive, because it
merely “runs down”.
The adjustment of the appropriate control travel and
directions for the motor control (speed control) is nor-
mally carried out in the »Control adjust« menu in the
“- trv +” column. Alternatively, these settings can also
be made in the menu …
»Servo adjustment« (page 112)
S4
S5
S6
Rev cent
+
trv
0%
0%
0%
100%
100%
100%
100%
100%
100%
0%
0%
100%
100%
100%
100%
S7
S8
Example 2
2-way switch usage
This variant realizes a purely ON/OFF function.
On the receiver side, either a simple electronic switch
or if a gentle motor start-up, for example, is de-
sired an appropriate motor control (speed control) is
required.
With the exception of assigning a different operating
element, the settings required for this are essen-
tially the same as those described under Example 1.
Therefore, the same comments and recommenda-
tions also apply.
Apart from the infinitely variable motor control under
Example 1 and the two-stage motor control in this
example, the selection of the two transmitter control
types only has an effect on the type of timer control,
see page 294.
Only the nature of the assignment and representation
of the selected switch in the display of the menu …
If you need to adjust the travels to suit the speed
controller, use one of the arrow buttons to move right
to the “- Travel +” column, following the right-pointing
triangle at bottom left:
In5
– travel +
+100%
+100%
+100%
+100%
In6
In7
In8
+100%
+100%
+100%
+100%
This fields of this column can be use to set the travel
required, even asymmetric if necessary.
A simultaneous tap on the  keys of the left four-
way button now will switch over to the »Servo dis-
play« where the selected proportional control can be
activated to watch the bars for channel 8 “wander”
from one side to the other and back.
However, if the proportional control is moved too
fast in practice the resulting sudden motor ac-
celeration can briefly strain the entire drive train (too
much). In this case, be sure to enter a value in the
“- time +” column to counteract such a condition.
Therefore, using one of the selection keys, switch
one column to the right, to the “- time +” column then
move the selected control close to “full throttle” so the
marker frame is only placed around one value field.
Now enter a value of at least 1 s …
In5
– time +
0.0s
0.0s
0.0s
1.1s
In6
In7
In8
0.0s
0.0s
0.0s
0.0s
… with which a movement of the proportional control
in the “ON” direction which is too fast is processes
move gently, and you can check immediately this by
switching to the »Servo display«.
»Control adjust« (page 118)
… differ. As in example 1, change over to the line of
a free input, activate the “Switch assignment” in the
second column as described on page 68, then
move the selected switch, in this case for example
switch 2, from the desired motor OFF position in the
direction of motor ON:
In5
offset
0%
0%
0%
–––
0%
In6
In7
In8
–––
–––
–––
GL
GL
GL
GL
typ
fr
fr
fr
2
Here again as already mentioned earlier in this
section leave the standard default “GL in the “Typ”
column.
The setting of the appropriate control travel for the
motor control (speed control) is made in the “- trv +”
column. If the motor should up gently with the use of
a motor control (speed control), an appropriate delay
time can be set as described in Example 1 in the
“- time +” column:
In5
– time +
0.0s
0.0s
0.0s
1.1s
In6
In7
In8
0.0s
0.0s
0.0s
0.0s
All other settings as already mentioned earlier in the
example are made analogous to Example 1. There-
fore, the same comments and recommendations also
apply.
Note:
No delay is entered on the “OFF” side, so that the
drive can be switched off instantly at any time. This
does not additionally stress the drive, because it