User manual

305Programming examples - Using flight phases
After the switch assignment is complete, use the se-
lection keys to switch to the bottom right and activate
the assignment of phase names with a brief tap on
the center SET key of the right four-way button.
Now close for example switch “6” by moving the se-
lected 3-way switch forward.
Assign the name “<2 Thermal>” to this switch position
and leave the name of its “OFF” position as “<1 nor-
mal>”.
A B
C D E F
6
5
2 Thermalv
Phase assignment
prior
combi
A B
C D E F
6
5
1 normal
Phase assignment
prior
combi
Finally, move the 3-way switch to the rear toward
“5”-position and assign this switch position the name
“<3 Speed>”:
A B
C D E F
6
5
3 Speed
Phase assignment
prior
combi
The phase names selected in the programming are
now shown, depending on the switch status, in all
flight-phase dependent menus, see the table on
page 150.
Since we have already made some settings in flight-
phase dependent menus, such as in the »Wing
mixers« menu, we will now copy these settings to the
«Thermal» flight phase. For this purpose, open the
menu …
»Copy/Erase« (page 80)
… and switch to the “Copy flight phase” line:
=>
=>
=>
=>
=>
=>
Copy flight phase
Erase model
Copy model–>model
Export to SD
Import from SD
All seven possible flight phases are listed in “Copy
from phase”:
Select the flight phase to be copied, e. g. “1 Normal”.
7
Copy from phase:
3
5
2
4
6
1
normal Thermal
Speed
With a brief tap on the center SET key of the right
four-way button, switch the window to entry of the
target memory “Copy to phase”.
Select phase “2 Thermal” as the target:
7
Copy to phase:
3
5
4
6
1
normal
Speed
Thermal2
Confirm the selection with a brief tap on the center
SET key of the right four-way button.
A security query follows, who should be confirmed
with “Yes”:
Phase to:
to be copied?
NO
1 Normal
2 Thermal
YES
Then repeat the process with flight phase “3 Speed”.
Now we will program the required settings in the
flight phase “Thermal” as an example.
In order to vary camber flap positions in the «Ther-
mal» phase, it is merely necessary to switch over to
the menu …
»Control adjust« (page 118)
… then change Input 6 as described beginning on
page beginning on page 118 from “GL(obal)” to
“PH(ase)” and finally assign it to an operating ele-
ment.
To do this, first use the selection keys to switch into
the “typ” column for “In6” and change this setting from
“GL to “PH”:
In6
offset
0%
0%
0%
–––
0%
In7
In8
In9
–––
–––
PH
GL
GL
GL
typ
Ther mal
fr
fr
Cn1
8
–––
SEL
Thereafter change one column to the right into the
column above SEL
In6
offset
0%
0%
0%
–––
0%
In7
In8
In9
–––
–––
PH
GL
GL
GL
typ
Ther mal
fr
fr
Cn1
8
–––
SEL
… and now assign this input, as described in the sec-