User's Manual

125
Program description: Telemetry menu
The servo follows the stick movement with a linear
response.
C: EXPO = +100% and DUAL RATE = 70%
The servo responds slowly to stick movements
around the neutral position, but the curve becomes
steeper with increasing control travel.
Note:
The control characteristics programmed at this point
also affect mapped receiver outputs.
RX SERVO TEST
RX SERVO TEST
ALL–MIN : 1000μsec
ALL–MAX : 2000μsec
ALARM VOLT : 3.8V
TEST : STOP
ALARM TEMP–:–10°C
ALARM TEMP+: 70°C
CH OUTPUT TYPE:ONCE
Value Explanation Possible settings
ALL-MAX Servo travel on
the “+” side for all
servo outputs in
the servo test
1500 … 2000 µs
ALL-MIN Servo travel on
the “-” side for all
servo outputs in
the servo test
1500 … 1000 µs
TEST Test procedure START / STOP
ALARM
VOLT
Alarm limit for the
receiver low-
voltage warning
3,0 … 6,0 V
Default setting:
3,8 V
ALARM
TEMP+
Alarm limit for
excessive receiver
temperature
50 … 80 °C
Default setting:
70 °C
ALARM
TEMP–
Alarm limit for
excessively
low receiver
temperature
-20 … +10 °C
Default setting:
-10 °C
CH OUTPUT
TYPE
Channel sequence ONCE, SAME,
SUMI, SUMO
ALL MAX (maximum servo travel)
In this line you can set the maximum servo travel for the
servo test on the plus side of control travel.
2000 µs corresponds to full travel, 1500 µs corresponds
to the neutral position.
ALL MIN (minimum servo travel)
In this line you can set the maximum servo travel for the
servo test on the minus side of control travel.
1000 µs corresponds to full travel, 1500 µs corresponds
to the neutral position.
TEST
In this line you can start and stop the receiver’s integral
servo test.
Press the central SET button of the right-hand four-way
b
utton to activate the input fi eld:
RX SERVO TEST
ALL–MIN : 1000μsec
ALL–MAX : 2000μsec
ALARM VOLT : 3.8V
ALARM TEMP–:–10°C
ALARM TEMP+: 70°C
CH OUTPUT TYPE:ONCE
TEST : STOP
Now select START with one of the arrow buttons of the
right-hand four-way button:
RX SERVO TEST
ALL–MIN : 1000μsec
ALL–MAX : 2000μsec
ALARM VOLT : 3.8V
ALARM TEMP–:–10°C
ALARM TEMP+: 70°C
CH OUTPUT TYPE:ONCE
TEST : START
Press the central SET button of the right-hand four-way
button to start the test-run. The input fi eld now reverts
from highlighted to “normal”:
RX SERVO TEST
ALL–MIN : 1000μsec
ALL–MAX : 2000μsec
ALARM VOLT : 3.8V
ALARM TEMP–:–10°C
ALARM TEMP+: 70°C
CH OUTPUT TYPE:ONCE
TEST : START
To stop the servo test, re-activate the input fi eld as de-
scribed previously, then select STOP and confi rm your
choice with the SET button of the right-hand four-way
button.
33112_mx12_HoTT_2_GB.indd Abs45:12533112_mx12_HoTT_2_GB.indd Abs45:125 06.06.2011 19:39:4306.06.2011 19:39:43