User's Manual
175
Appendix
Graupner HoTT General Engine Module
Order No. 33610
General sensor for Graupner HoTT receivers and models with internal-
combustion or electric power system:
2 x temperature and voltage measurements with warning thresholds •
for min. and max. voltage and min. and max. temperature
Individual cell measurement with min. voltage warning thresholds•
Voltage, current and capacity measurement with warning thresholds •
for min. and max. voltage, max. capacity and max. current
Programmable current limiting•
Current measurement with 2 x 1 mOhm shunt resistors in parallel = •
0.5 mOhm
Rev-count measurement and warning thresholds for min. and max. •
rotational speed
Fuel measurement with warning thresholds in 25% increments (re-•
quires software update)
User-variable warning time: OFF, 5, 10, 15, 20, 25, 30 seconds, con-•
stant
User-variable warning repeat time: constant, 1, 2, 3, 4, 5 min, once•
2 x temperature measurement, optionally 0 to 120°C or 200°C, also •
voltage measurement up to 80 V DC
1 x rev-count measurement up to 100,000 rpm with two-blade pro-•
peller
1 x speed controller / servo input, 1 x speed governor input, 1 x •
speed controller / servo output for rotational speed governor
etc. see product at www.graupner.de•
Graupner HoTT General Air Module
Order No. 33611
General sensor for Graupner HoTT receivers and models with internal-
combustion or electric power system:
Vario with altitude signals, climb and descent signals, and addition-•
al warning thresholds for min. altitude, max. altitude, climb and two-
stage descent rate
Altitude indicator (-500 … +3000 m), storage of min. and max. alti-•
tude
2 x temperature and voltage measurements with warning thresholds •
for min. and max. voltage and min. and max. temperature
Individual cell measurement with min. voltage warning thresholds•
Voltage, current and capacity measurement with warning thresholds •
for min. and max. voltage, max. capacity and max. current
Rev-count measurement and programmable speed governor, also •
warning thresholds for min. and max. rotational speed
Fuel measurement with warning thresholds in 25% increments (re-•
quires software update)
User-variable warning time: OFF, 5, 10, 15, 20, 25, 30 seconds, con-•
stant
User-variable warning repeat time: constant, 1, 2, 3, 4, 5 min, once•
2 x temperature measurement, optionally 0 to 120°C or 200°C, also •
voltage measurement up to 80 V DC
1 x rev-count measurement up to 100,000 rpm with two-blade pro-•
peller
etc. see product at www.graupner.de•
Graupner HoTT Electric Air-Module
Order No. 33620
General sensor for Graupner HoTT receivers and electric-powered
models:
Vario with altitude signals, climb and descent signals, and addition-•
al warning thresholds for min. altitude, max. altitude, two-stage climb
and descent rate
Altitude indicator (-500 … +3000 m), storage of min. and max. alti-•
tude.
2 x temperature and voltage measurements with warning thresholds •
for min. and max. voltage and min. and max. temperature
Individual cell measurement 2 ... 14S with min. voltage warning •
thresholds
Voltage, current and capacity measurement with warning thresholds •
for min. and max. voltage, max. capacity and max. current
User-variable warning time: OFF, 5, 10, 15, 20, 25, 30 seconds, con-•
stant
User-variable warning repeat time: constant, 1, 2, 3, 4, 5 min, once•
2 x temperature measurement, optionally 0 to 120°C or 200°C, also •
voltage measurement up to 80 V DC
1 x speed controller input, 1 x speed controller output for power re-•
duction due to low voltage of individual cells
1 x current, voltage and capacity measurement, up to 150 A (peak 1 •
sec. 320 A) and up to 60 V
1 x individual cell monitoring for 2 - 14S Lithium batteries (LiPo, LiIo, •
LiFe)
etc. see product at www.graupner.de•