User's Manual

59
Program description: base settings - fi xed-wing model
timer
Two timers are shown in the basic display: one stop-
watch and one fl ight timer:
GRAUBELE
#01
0:00h
stop
flt
K78
0:00
0:00
0.0V
6.1V
HoTT
M
99%
You can assign a physical switch or a control switch to
these tw
o timers in the right-hand column of the “timer”
line, indicated by the switch symbol at the bottom
edge of the screen.
motor at C1
idle re.
tail type normal
cut off +100%–125% 1
aile/flap 2aile
timer
0:00 –––
The assigned switch starts both timers, and also halts
the stopwatch.
The method of assigning a physical switch or a control
switch is described on page 39.
The fl ight timer, and the saving of telemetry data on
a memory card fi tted in the card slot (see page 22),
always starts simultaneously with the stopwatch, but
continues to run even when the stopwatch is halted
(switched off). It can only be stopped by pressing the
central ESC button of the left-hand four-way button
when the stopw
atch is already halted.
Once the timers are stopped, you can reset both timers
to their initial value by simultaneously pressing the cd
or ef buttons of the right-hand key (CLEAR).
Switching between “count-up” and “count-down”
Count-up timer (stopwatch function)
If you assign a switch and start the stopwatch with the
initial value of “0:00”, the timer runs up until the maxi-
mum of 180 minutes and 59 seconds, then re-starts at
0:00.
Count-down timer (alarm timer function)
You can select a starting time within the range 0 to 180
minutes in the left-hand minutes fi eld, and a starting
time within the range 0 to 59 seconds in the right-hand
seconds fi eld. Any combination of times can also be
selected.
Simultaneously pressing the cd or ef buttons of the
right-hand four-way button (CLEAR) resets any settings
you have made to “0” or “00”.
motor at C1
idle re.
tail type normal
cut off +100%–125% 1
aile/flap 2aile
timer
0:00
3
Procedure
Select the desired input fi eld using the arrow buttons 1.
ef of the left or right-hand four-way button.
Press 2. SET in the centre of the right-hand four-way
b
utton.
Select the required time in the highlighted minutes 3.
and seconds fi elds using the arrow buttons of the
right-hand four-way button.
Press the central 4. SET button to conclude the input
process.
Once you have switched back to the basic display 5.
by pressing the central ESC button of the left-hand
f
our-way button the required number of times, press
the cd or ef buttons of the right-hand four-way
button (CLEAR) simultaneously, with the stopwatch
stopped, to switch the stopwatch to the “Timer” func-
tion; see top right in the following illustration:
GRAUBELE
#01
0:00h
stop
flt
K78
10:01
0:00
0.0V
6.1V
HoTT
M
99%
When you operate the assigned switch, the stopwatch
no
w starts from the set initial value, counting down
(“Timer function”). When the set time has elapsed, the
timer does not stop, but continues to run so that you can
read off the time elapsed after reaching zero. To make
this clear, the over-run time is shown highlighted (black
background).
Sequence of sounds
30 sec. before zero: triple beep
single beep every two seconds
20 sec. before zero: double beep
single beep every two seconds
10 sec. before zero: single beep
single beep every second
5 sec. before zero: single beep every second at higher
rate
zero: longer beep; display switches to
inverse video
33112_mx12_HoTT_2_GB.indd Abs24:5933112_mx12_HoTT_2_GB.indd Abs24:59 06.06.2011 19:39:3806.06.2011 19:39:38