User's Manual

86
Program description: Phase trim – fi xed-wing model
Phase trim
Flight phase-specifi c trims for fl aps, ailerons and elevator
If you wish to enter values other than “0”, e. g. to have
more lift at launch, or to be able to fl y more slowly
when thermalling, or faster when fl ying speed tasks, but
WITHOUT having to change the basic settings each
time, then you need to use alternative fl ight phases. This
is done by activating “Phase 2” and, if necessary, “Phase
3” in the “Basic settings menu.
This is accomplished by moving to the “Basic settings
menu and assigning a switch to the selected phase or
phases. If you decide to use one of the three-position
switches SW 4/5 or 6/7 as the phase switch, then it is
advisable to assign it to the “Speed” phase and “Launch”
phase at the extremes, with “normal” at the centre posi-
tion.
Notes:
At the centre position of SW 4/5 or 6/7 the switch
symbols on the screen should look as in the picture
at top right.
Please note the priorities of the individual fl ight phas-
es, as described in detail on page 60.
The default name for “Phase 2” is “Launch”, and that for
“Phase 3” is “Speed”. However, you can assign your own
choice of names at any time by selecting the appropriate
line, pressing the central SET button of the right-hand
f
our-way button, and selecting one of the following
names in the highlighted fi eld using the arrow buttons of
the right-hand four-way button.
take off
thermal
dist(ance)
speed
acro
landing
If you have not assigned a switch to phases 2 or 3 in
the “Basic settings menu, i. e. you have not assigned
switches to these alternative phases, you automatically
remain in fl ight phase 1 - “normal”.
The number and name (“normal”) of this fl ight phase
are permanently assigned, and cannot be altered. For
this reason the “normal” phase is not stated as Phase
1 “normal” in the “Basic settings menu; it is simply
concealed.
10:01 3
phase 2
phase 3
takeoff
speed
–––
–––
aile/flap 2aile
timer
tail type normal
If you select the Phase trim
menu with this basic
arrangement, you will fi nd just the “normal” line on the
screen, whose pre-set values of 0% are not usually
altered.
P H A S E T R I M
normal
¿
0%
0%
0%
AIL ELEFLA
Note:
In this menu you will have at least one control function
(ELE), and a maximum of three functions (ELE, AIL and
FLA), available for phase-specifi c trim settings, depend-
ing on the settings you have entered in the “Aileron /
ap” line of the Basic settings menu (see page 58).
air-tow
test
timer 10:01
phase 2
phase 3
takeoff
speed
6
7
3
receiv out
aile/flap 2aile
These names will appear in the transmitter’s basic
displa
y …
GRAUBELE
#01
2:22h
stop
flt
«normal »
K78
0:00
0:00
5.5V
51%
5.2V
HoTT
M
… and in the “Phase trim
menu - see lower picture.
Setting up fl ight phase trims
In the “Phase trim” menu you can adjust the trims for the
previously selected fl ight phases.
The fi rst step is to use the phase switch you have
already assigned to move to the phase which you wish
to adjust (the “
*
at far left indicates the currently active
phase).
P H A S E T R I M
normal
¿
0%
0%
0%
takeoff
speed
0%
0%
0%
0%
0%
0%
AIL ELEFLA
33112_mx12_HoTT_2_GB.indd Abs31:8633112_mx12_HoTT_2_GB.indd Abs31:86 06.06.2011 19:39:4006.06.2011 19:39:40