Manual

OPERATOR’S MANUAL
Auto Section Control System
11001-1561B-201207
INTELLIAG PDC SETUP / 19
Figure 20
Clutch Delay Times
Contact DICKEY-john Technical Support at 1-800-637-3302 for
recommended shutoff delay times on all other clutches.
Figure 21
Clutch Configuration Screen
ASSIGNING ROWS
The Clutch Configuration screen assigns rows to outputs. As rows are
assigned to each output, row numbers automatically populate.
1. At the Clutch Module screen, press the Clutch Configuration button.
Enter number of rows to be assigned to each output.
Figure 22
Clutch Configuration
Clutch Type Turn Off Turn On
TruCount 0.4 seconds 0.4 seconds
Great Plains 0.3 seconds 0.4 seconds