TROUBLESHOOTING
PROBLEM
Water leaking from the indoor
unit into the room.
The unit will not deliver air.
CAUSE/SOLUTION
Cause: While it is normal for the system to generate condensate water in
cooling mode, it is designed to drain this water via a condensate drain system
to a safe location.
Solution: If water is leaking into the room, it may indicate one of the following.
The indoor unit is not level right to left. Level indoor unit.
The condensate drain pipe is restricted or plugged. All restrictions must
be removed to allow continuous drainage by gravity.
If problem persists, contact a qualified service professional for assistance.
Cause: There are a number of system functions that will prevent air flow.
Solution: Check for the following:
In heating mode, the indoor fan may not start for three minutes if the
room temperature is very low. This is to prevent blowing cold air.
In heat mode, if the outdoor temperature is low and humidity is high,
the system may need to defrost for up to 10 minutes before beginning
a heating cycle.
In dry mode, the indoor fan may stop for up to three minutes during
the compressor off delay.
Otherwise, you should contact a qualified service professional for
assistance.
28