Installation guide

SYSTEM
CONFIGURATION
VENTILATION
CONTROL
The
ventilation
control
lever
is
located
at
left
side
of
unit,
behind
front
panel.
NOTE:
The
vent
door
shipping
hardware
must
be
removed
before
using
vent
control
lever.
See
See
figure
9.
When
set
at
CLOSE,
only
the
air
inside
the
room
is
circulated
and
filtered.
When
set
at
OPEN,
some
outdoor
air
will
be
drawn
into
room.
This
will
reduce
heating
or
cooling
efficiency.
Energy
Tip:
Keep
the
vent
control
at
CLOSE.
Room
air
will
be
filtered
and
circulated.
Vent
Control
(Pull
lever
through
label
to
operate.)
Fig.
16
Ventilation
Control
Location
ADJUSTING
AIR
DIRECTION
To
adjust
air
direction:
1.
Remove
front
panel.
See
Fig.
10.
2.
Remove
louver
screws
that
hold
louver
insert
in
place
(from
back
side
of
front
panel).
See
Fig.
17.
3.
Turn
louver
insert
and
rotate
180°.
See
Fig.
18.
4,
Replace
louver
insert.
5.
Replace
screws
and
front
panel.
Air
discharge
upward
Louver
screws
Louver
screws
Fig.
17
Backside
of
Front
Panel
Air
discharge
outward
(Default)
Fig.
18
Adjusting
Louvers
10