ETAC Product Data Guide
16
FIELD--INSTALLED ACCESSORIES (CONT.)
Leveling Legs
Part No.: LEVELING--LEGS
Leveling legs attach easily to the wall sleeve and
offer accurate leveling and support for units without
a subbase. Leveling legs are adjustable from 3--1/4 to
5--1/2 inches (82.6 to 139.7 mm).
Leveling Legs
Hardwire Kit
Conduit Interface Kit
Part No.: HARDWIRE-KIT-1PK
Part No.: CONDUIT-INTF-1PK
This accessory hardwire kit provides a permanent
connection to the unit. Electrical hard wiring is
required when NEC (National Electrical Code) or
local codes restrict the use of power cord and plug
connections. The hardwire kit mounts on the front
right side of the unit and comes with 36 inches of
flexible steel conduit and a Molex connector for easy
connect/disconnect.
The conduit interface accessory kit provides the wire
connection to the unit to interface to existing
installed conduit.
Hardwire Kit
Conduit Interface Kit
Extra Long Replacement 265v Power Cord
Extra Long
Replacement 265V
Power Cord
2
0
1918
17
16
15
14
1
3
1
2
1
1
10
9
8
7
6
5
4
3
2
1
Part No. PWRCORD-265V-15A
PWRCORD-265V-20A
PWRCORD-265V-30A
The Extra Long Replacement 265v power cord
extends 58 inches from bottom of front panel to the
plug head. Do not use where prohibited by codes or
regulations.
APPLICATIONS
• Hotels and motels
• Nursing homes and assisted living care
centers
• Offices
• Apartments
• Single--family dwellings
• Home conversions and residential add--ons
NEW CONSTRUCTION
ADVANTAGES FOR NEW
CONSTRUCTION
Design Flexibility for the Architect/Engineer
• Whisper--quiet performance, indoors and out
• No bulky duct system
• No separate equipment room
• No water towers or additional cooling
equipment
• No complex match--up of different HVAC
components
• Less sensitivity to building orientation (sun,
wind, shade)
• Optional architectural grille to permit custom
exterior appearance
I nitial Cost Savings for the Buildin
g Owner
• N
o expensive component HVAC system
purchase
• No equipment room or maintenance
engineering staff
• Two--part delivery to minimize on--site
damage
• Weather--protected wall sleeve that goes in
place during construction; chassis that slides
in place after construction
• No seasonal changeover required for cooling
or heating -- units are self--contained comfort
systems
Lower Operating Costs and Reliable Comfort
for The Occupant
• Heat pump models offer substantial savings
over models with conventional electric
resistance heaters
• Individual units allow tenants to choose the
degree of comfort and operating economy.
• Rapi
d servicing reduces downtime: complete
chassis can be replaced in minutes without
disrupting other occupants.
• Each unit operates independently of other
units in the building. No dependency by
building on central HVAC system.
RETROFIT/REPLACEMENT
If you are replacing a unit in an existing wall sleeve,
your options include:
• Replace the existing wall sleeve with the
the polymer wall sleeve. See accessory sleeve
section for selecting the correct sleeve for
your application.
NOTE: in most cases, when replacing the
wall sleeve, the exterior grille must also be
replaced.
• Use an existing sleeve and exterior grille. The
Gree E-TAC will fit into:
—
— Friedrich T series and ZoneAire wall
sleeves, with a required wall sleeve
ex
tension (see accessory Friedrich
Retrofit Wall Sleeve Adapter).
E-TAC
Whether you are designing a new structure or
replacing packaged terminal air conditioning units in
an existing building, Gree E-TAC will meet your
needs.
The Gree E-TAC Packaged Terminal Air Conditioning
(E-TAC) unit is designed to meet the needs of the
architect, engineer, and contractor. For unit
installation, Gree’s expert support network will assist
in all applicable aspects of the construction project,
from preparing a budget to start-up.
4
The following major competitors’ wall
sleeves/grilles: Carrier, GE, Amana,
Trane, Friedrich and Bryant, and NO
accessory retrofit kit is required.