INSTALLATION MANUAL Electric Heater Kit MODELS: FLEXX24HP230V1AH&BH FLEXX36HP230V1AH&BH FLEXX48HP230V1AH&BH FLEXX60HP230V1AH&BH Thank you for choosing our product. Please read this Installation & Owner’s Manual carefully before operation and retain it for future reference. If you lose this Manual, please contact your local distributor visit www.greecomcomfort.com/resources now to download an file the electronic version.
ATTENTION INSTALLING PERSONNEL Prior to installation, thoroughly familiarize yourself with this Installation Manual. Observe all safety warnings.
CAUTIONS ENSURE THAT ALL POWER IS DISCONNECTED PRIOR TO ATTEMPTING INSTALLATION OF THIS HEATER KIT. THERE MAY BE MORE THAN ONE DISCONNECT SERVICING THE UNIT. A MEANS OF STRAIN RELIEF AND CONDUCTOR PROTECTION MUST BE PROVIDED AT THE SUPPLY WIRE ENTRANCE INTO CABINET.
1. Remove the front panel and upper access panel from the air handler. 2.
3. Remove the electrical box 4.
5. Install the electric heater to the metal plate position which disassembles in step 4.
6. Install breaker (Notes: When installation, you need to lift up the buckle first, hold the breaker bracket and then put down the buckle to fix the breaker) 7.
. After installation, the schematic diagram is as follows: 9. Install the electrical box back to the original position 10. Install the front panel and upper panel back to the air handler. Electric heater installation is completed.
Electric Heater Kits Model Optional electric electri heater Cooling capacity(ton) FLEXX24,36HP230V1AH OR BH 2.0 / 3.0 FLEXXHTR5KW 5 FLEXX24,36HP230V1AH OR BH 2.0 / 3.0 FLEXXHTR8KW 8 FLEXXHTR10KW 10 FLEXX36,48,60HP230V1AH OR BH 3.0 / 4.0 / 5.0 FLEXX48,60HP230V1AH OR BH 4.0 / 5.0 FLEXXHTR15KW 15 FLEXX48,60HP230V1AH OR BH 4.0 / 5.
U.S. CONTACT INFORMATION TRADEWINDS, LLC E-mail: info@twclimate.com Contractor Support: 888-850-7928 | Mon-Fri 8 AM - 5 PM EDT G R E E C O M F O R T .