2 Product Introduction
2.1 Operating Range
—
Cooling
Heating
Outdoor
temperature
5
°
F(-15°C)~129.2
°
F (54°C) -22
°
F (-30°C)~75.2
°
F (24°C)
2.2 Standard Accessories
Outdoor unit accessories
No.
Name
Appearance
Q'ty
Usage
1 Drain plug
3
To plug the unused drain
hole
2
Drainage
connecter
or
1
To connect with the hard
PVC drain pipe
2.3 Optional Accessories
Outdoor unit accessories
No.
Name
Appearance
Q'ty
Usage
1
Adapter
pipe
1
Connect the
unit with the
liquid pipe
2
Adapter
pipe
1
Connect the
unit with the
gas pipe
3 Installation
3.1 Installation Preparation
3.1.1 Selection of Installation Location
①. The unit must be installed properly supported to withstand the weight of the
unit and fixed securely, otherwise the unit would topple or fall off.
②. Install the air conditioner at a place where the inclination is less than 5°.
③. Avoid installing the unit in direct sunlight to improve efficiency.
④. Do not install where there is the danger of combustible gas leakage.
⑤. Do not install the unit at a place with leakage of flammable gas.